NAYCWY preto 4 x 70 sm / 35 mm²

NAYCWY preto 4 x 70 sm / 35 mm² Código do artigo 32844
  • Certificação EAC
  • Certificação VDE
  • Certificação UKCA

Detalhes do artigo

Código do artigo
32844
Descrição do artigo
NAYCWY preto 4 x 70 sm / 35 mm²
Exterior Ø mm (aprox.)
38,6
Peso Especifico de Cobre kg/km
240,0
peso especifico do Aluminio (kg/km)
814,0
Peso kg/km (aprox.)
2074,0
Base de cobre em EUR / 100kg
0
base de Aluminio (EUR/100kg)
0
VPE/m
500, 1000
cortes individuais possíveis
sim
EAN/GTIN
4060892267994
Número da tarifa aduaneira
85444995

Dados técnicos

Power distribution cable acc. to DIN VDE 0276-603 / HD 603 S1 / IEC 60502
Temperature range flexing -5°C to +50°C
fixed installation -40°C to +70°C
Permissible conductor operating temperature +70°C
Permissible short circuit temperature (short circuit duration max. 5 s) +160°C
Nominal voltage U0/U 600/1000 V
Test voltage 4000 V
Highest permissible voltage Direct current systems: Conductor/conductor 1.8 kV
Direct current systems: Conductor/earth 0.9 kV
Alternating current systems: Single phase systems both outer conductors insulated 1.4 kV
Alternating current systems: Single phase systems one outer conductor earthed 0.7 kV
Three phase systems 1.2 kV; with concentric conductor and a cross section of 240 mm² and above 3.6 kV
Minimum bending radius 12x Outer-Ø

Detalhes

Estrutura do cabo

      • Aluminium conductor,
      • single wire acc. to DIN VDE 0295 cl.1 / IEC 60228 cl.1
      • multi wire acc. to DIN VDE 0295 cl.2 / IEC 60228 cl.2
      • Core insulation: PVC, compound type DIV4 acc. to HD 603 S1
      • Core identification acc. to DIN VDE 0293-308
      • Cores stranded in concentric layers
      • Filling compound
      • Concentric conductor
      • (Ceander), inner layer of corrugated copper wires
      • outer layer of copper tape as counter helix
      • Outer sheath: PVC, compound type DMV5 acc. to HD 603 S1
      • Sheath colour: black

Propriedades

      • the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers

Testes

      • Flame retardant acc. to DIN VDE 0482-332-1-2 / DIN EN 60332-1-2 / IEC 60332-1-2

Notas

      • re = round conductor, single wire
      • rm = round conductor, multi wire
      • sm = sectional conductor, multi wire
      • Part no. 17000053 in reference to VDE Designation (N)AYCWY
      • The conductor is metrically constructed (mm²). The AWG designation is approximate and purely informative.

Aplicação

      • Power distribution cables, preferably used for underground installation, primarily in local networks, for industrial applications and switching systems, power stations. Wherever increased electrical and mechanical protection are required. Installation in water, outdoors, in concrete, indoors and in cable ducts. The concentric conductor (C) may be used as PE, PEN conductor or as a shield according to national regulations. The corrugated design (Ceander) of the conc entric conductor permits any number of cable junctions during assembly, without any conductors having to be cut. This ensures a optimal reliability.
Info Circlechevron-leftAlertBrowse fileDownload fileFileImagePdfWordTextExcelPowerpointArchiveCsvAudioVideoSpinnerCalendarSort NoneSort ASCSort DESCReturn arrowMinusYouTubeSyncVisibleInvisible