TOPSERV® 600 VFD
  • UL Certification
  • CSA Certification
  • EAC Certification
  • UV-resistant
  • Suitable For Drag Chains
  • Length Marking In Feet
  • UKCA Certification
  • Oil Res I/II
  • exposed run: TC-ER, PLTC-ER, ITC-ER, NFPA 79
  • EMC-preferred type
Buy items

Technical Data

Motor and servo cable acc. to UL Std. 1277 (TC-ER), UL Std. 2277 (WTTC), CSA Std. C22.2 No. 210 - AWM I/II A/B, CSA Std. C22.2 No. 230 & 239 - c(UL) CIC-TC, UL Std. 2250 (ITC-ER), UL Std. 13 (PLTC-ER), 18 AWG - 12 AWG: UL Std. 2250 (ITC-ER), UL Std. 13 (PLTC-ER), 14 AWG - 2 AWG: UL Std. 44 (RHW-2)
Temperature range flexible +5°C to +50°C
fixed -40°C to +105°C
UL (TC) to +90°C
Nominal voltage UL (TC) AC 600 V
UL (WTTC) AC 1000 V
CIC-TC AC 600 V
Test voltage conductor/conductor 6000 V
Test voltage conductor/shield 6000 V
Minimum bend radius flexible 10x Outer Ø
fixed 5x Outer Ø

Details

Cable Structure

      • Copper wire tinned, finely stranded acc. to ASTM B174 Class M (18-10 AWG) / ASTM B174 Class K (8-2 AWG), AWG sizes
      • Conductor insulation: XLPE
      • Conductor identification: black conductors with consecutive white numbers
      • G = with GN-YE ground, in the outer layer
      • Conductors stranded in layers with optimally matched lay lengths
      • Fleece wrap
      • Shield: tinned copper braided shield, approx. coverage 85%
      • Fleece wrap
      • Outer jacket: Special TPE
      • Jacket color: see datasheet
      • Length marking: in feet

Properties

      • resistant to: oil, UV radiation (SUN RES)
      • for outdoor use
      • direct burial (DIR BUR)
      • suitable for use in drag chains

Tests

      • oil-resistant acc. to UL Std 1277 Tab. 12.2, Oil Res I / Oil Res II
      • Cold Bend Test acc. to UL Std. 1277 No. 17
      • Impact Test (-ER) acc. to UL Std. 1277 No. 23
      • Crushing Test (-ER) acc. to UL Std. 1277 No. 24
      • direct burial (DIR BUR) acc. to UL Std. 1277 No. 5 (wet-locations insulation), No. 19 (crushing test)
      • Vertical-Tray Flame Test (FT4) acc. to UL Std. 1277 No. 15 / UL Std. 1685
      • certifications and approvals:
      • EAC
      • ECOLAB®
      • for Class 1 Div. 2 explosive environments acc. to NEC Art. 501

Notes

      • Conductor sizes are based on the AWG measurement system, metric conductor sizes (mm²) are approximated and are for reference only
      • for use in drag chain systems:
      • 1) the assembly instructions must be observed
      • 2) for special applications, we recommend contacting us and using our drag chain system inquiry form

Application

      • Highly flexible, extremely oil-resistant motor supply cable for modern servomotors; the tinned copper braid screen (approx. 85% coverage) provides effective protection against electrical disturbances and the resultant failures. For open, unprotected installation in cable trays and from cable trays to the machine. The special TPE sheath is extremly resistant to oil, coolants and solvents and hence the perfect solution for industrial applications with open installation, installation in pipes or in earth.

Items TOPSERV® 600 VFD

Cross Section (mm²)
AWG No.
Outer Diameter
Outer Jacket Color
Item description
Part no.
Jacket color Cross-sec. mm² (approx.) Outer Ø mm (approx.) Cu factor per km
Info Circlechevron-leftAlertBrowse fileDownload fileFileImagePdfWordTextExcelPowerpointArchiveCsvAudioVideoSpinnerCalendarSort NoneSort ASCSort DESCReturn arrowMinusYouTubeSyncVisibleInvisible