TOPFLEX®-EMV-UV-3-PLUS-2YSLCYK-J
- double shielded
- improved EMC properties due to protective conductor (GN-YE) divided into thirds
- for outdoor use
- 3x16 + 3G2.5 mm² and larger: suitable for direct burial
Technical Data TOPFLEX®-EMV-UV-3-PLUS-2YSLCYK-J
Motor connection cable for frequency converters in alignment with DIN VDE 0250 | |
Temperature range | flexible -5°C to +70°C fixed -40°C to +70°C |
Nominal voltage | AC U0/U 600/1000 V |
Max. permissible operating voltage | alternating current (AC) conductor/ground 700 V three-phase alternating current (AC) conductor/conductor 1200 V direct current (DC) conductor/ground 900 V direct current (DC) conductor/conductor 1800 V |
Test voltage conductor/conductor | 4000 V |
Coupling resistance | see datasheet |
Minimum bend radius | flexing <12 mm: 10x Outer ø flexing >12 mm: 15x Outer ø fixed 4x Outer ø |
Details TOPFLEX®-EMV-UV-3-PLUS-2YSLCYK-J
Cable Structure
-
- Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 / IEC 60228 Class 5
-
- Conductor insulation: PE
-
- Conductor identification: brown, black, gray, green-yellow (divided into thirds)
-
- Ground conductor: GN-YE divided into thirds (3+3 conductor structure)
-
- Conductors stranded with optimal lay lengths
-
- 1. Shield: plastic-coated aluminum foil (St)
- 2. Shield: tinned copper braided shield, approx. coverage 85%
-
- Outer jacket: Special-PVC
-
- Jacket color: black (RAL 9005)
-
- Length marking: in meters
Properties
-
- resistant to: UV radiation, weathering effects
-
- for outdoor use
-
- optimal shielding enables interference-free operation of frequency converters
-
- low coupling resistance ensures good electromagnetic compatibility
-
- low mutual capacitance of the individual conductors due to PE conductor insulation and low shield capacity, enable low power transmission loss
Tests
-
- flame-retardant acc. to DIN VDE 0482-332-1-2 / DIN EN 60332-1-2 / IEC 60332-1-2
-
- UV-resistant acc. to DIN EN ISO 4892-2
-
- weather-resistant acc. to DIN EN ISO 4892-2
-
- electromagnetic compatibility acc. to DIN VDE 0875-11 / DIN EN 55011
-
- minimum cross section of 0.75 mm² meets requirements acc. to DIN EN 60204-1
-
- certifications and approvals:
- EAC
Notes
-
- the conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only
Application
-
- Used as a connecting cable for medium mechanical stress with fixed installation and occasional free movement in dry, damp or wet rooms, as well as outdoors; direct burial installation is possible beginning with 3x16+3G2.5 mm². Used in automotive, food, packaging and chemical industries, as well as in the environmental technology sector. EMC = Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding.
Items TOPFLEX®-EMV-UV-3-PLUS-2YSLCYK-J
Item description
Part no.
|
AWG (approx.) | Outer Ø mm (approx.) | Cu factor per km | Weight kg/km (approx.) |
---|