TOPFLEX®-EMV-UV-3-PLUS-2XSLCYK-J UL/CSA
- enhanced current carrying capacity
- protective conductor (GN-YE) divided into thirds
- UV resistant
- double shielded
- EMC-preferred type
Technical Data TOPFLEX®-EMV-UV-3-PLUS-2XSLCYK-J UL/CSA
Motor connection cable for frequency converters acc. to UL Std. 758 (AWM) Style 21179, in alignment with DIN VDE 0250 | |
Temperature range | flexible -5°C to +90°C fixed -40°C to +90°C |
Conductor operating temperature | +90°C |
Nominal voltage | UL (AWM) AC 1000 V |
Test voltage conductor/conductor | 4000 V |
Coupling resistance | see datasheet |
Minimum bend radius | flexing <12 mm: 10x Outer ø flexing >12 mm: 15x Outer ø fixed 4x Outer ø |
Details TOPFLEX®-EMV-UV-3-PLUS-2XSLCYK-J UL/CSA
Cable Structure
-
- Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 / IEC 60228 Class 5
-
- Conductor insulation: XLPE
-
- Conductor identification: brown, black, gray, green-yellow (divided into thirds)
-
- Ground conductor: GN-YE divided into thirds (3+3 conductor structure)
-
- Conductors stranded with optimal lay lengths
-
- 1. Shield: plastic-coated aluminum foil (St)
- 2. Shield: tinned copper braided shield, approx. coverage 85%
-
- Outer jacket: Special-PVC
-
- Jacket color: black (RAL 9005)
-
- Length marking: in meters
Properties
-
- resistant to: UV radiation
-
- for outdoor use
-
- optimal shielding enables interference-free operation of frequency converters
-
- low coupling resistance ensures good electromagnetic compatibility
-
- low mutual capacitance of the individual conductors due to XLPE conductor insulation and low shield capacity, enable low power transmission loss
Tests
-
- flame-retardant acc. to DIN VDE 0482-332-1-2 / DIN EN 60332-1-2 / IEC 60332-1-2, CSA FT1
-
- electromagnetic compatibility acc. to DIN VDE 0875-11 / DIN EN 55011
Notes
-
- the conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only
Application
-
- Motor connection cable for fixed installations and applications with occasional free movement involving medium mechanical stress in dry, damp and wet rooms as well as outdoors. As a result of the permissible operating temperature of +90°C at the conductor, an enhanced current carrying capacity compared to PE insulated motor connection cables is permissible. For use in the automotive, food processing and packaging industry. EMC = Electromagnetic compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding.
Items TOPFLEX®-EMV-UV-3-PLUS-2XSLCYK-J UL/CSA
Item description
Part no.
|
AWG (approx.) | Outer Ø mm (approx.) | Cu factor per km | Weight kg/km (approx.) |
---|