RE-2Y(St)Yv PiMF
  • EAC Certification
  • Length Marking In Meters
  • UKCA Certification
  • Computer cable
  • reinforced outer jacket
  • PiMF: Pair in Metal Foil
  • overall Shield with drain wire
  • for outdoor use
  • with blue outer jacket: for intrinsically safe systems in explosion-endangered areas
Buy items

Technical Data

Computer cable in alignment with DIN VDE 0819-7 / DIN EN 50288-7
Temperature range flexible -5°C to +50°C
fixed -40°C to +70°C
Peak operating voltage 300 V (not for high power current installation purposes)
Test voltage conductor/conductor 2000 V
Test voltage conductor/shield 1000 V
Conductor resistance at 20°C 0.5 mm²: max. 39.2 Ohm/km
1.3 mm²: max. 14.2 Ohm/km
Mutual capacitance conductor/conductor at 800 Hz
0.5 mm²: approx. 75 pF/m
1.3 mm²: approx. 100 pF/m
Crosstalk attenuation at 60 kHz, 1.02 dB
(approx. value)
Inductance approx. 0.75 mH/km
Minimum bend radius flexible 15x Outer Ø
fixed 7.5x Outer Ø

Details

Cable Structure

      • Copper wire bare, stranded
      • Wire structure:
      • 0.5 mm²: 7 x 0.3 mm
      • 1.3 mm²: 7 x 0.49 mm
      • Conductor insulation: PE
      • Conductor identification: color coded, pairs:
      • conductor a = black; conductor b = white
      • with consecutive numbering 1/1, 2/2, etc.
      • x = without ground conductor
      • Conductors stranded in pairs with optimal lay lengths
      • Foil wrap of the pairs
      • Drain wire per pair, tinned copper, Diameter: 0.6 mm
      • Shielding element: pairs, plastic-coated aluminum foil (St), approx. overlap 25%
      • Pairs stranded in layers with optimal lay lengths
      • for multiple pair design: communication conductor, nominal cross section: 0.5 mm², Conductor insulation: PE, Conductor identification: orange
      • Foil wrap
      • Drain wire, tinned copper, stranded (0.5 mm² = 7 x 0.3 mm)
      • Shield: plastic-coated aluminum foil (St), approx. overlap 25%
      • Outer jacket: PVC, reinforced (v)
      • Jacket color: see datasheet
      • Length marking: in meters

Properties

      • for outdoor use
      • direct burial
      • PiMF: Pair in Metal Foil
      • low attenuation and operating capacities allow long transmission distances and short pulse transition times

Tests

      • flame-retardant acc. to DIN VDE 0482-332-1-2 / DIN EN 60332-1-2 / IEC 60332-1-2
      • certifications and approvals:
      • EAC

Notes

      • the conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only
      • copper weight including PiMF drain wires, copper stranded drain wires and communication conductor
      • with blue jacket for installation in intrinsically safe systems (ignition protection type -i-) in explosion-endangered areas according to DIN VDE 0165-1 / DIN EN 60079-14 / IEC 60079-14, Section 16.2.2

Application

      • Computer cables are used in data processing and process control. The individual screening of the pairs ensures good crosstalk attenuation values. When permanently installed, suitable for use in dry and damp rooms, outdoors and underground.

Items RE-2Y(St)Yv PiMF

No. of Conductors
No. of Pairs
Cross Section (mm²)
Outer Diameter
Outer Jacket Color
Item description
Part no.
Jacket color AWG (approx.) Outer Ø mm (approx.) Cu factor per km

Accessories

Products That Match This Product

Info Circlechevron-leftAlertBrowse fileDownload fileFileImagePdfWordTextExcelPowerpointArchiveCsvAudioVideoSpinnerCalendarSort NoneSort ASCSort DESCReturn arrowMinusYouTubeSyncVisibleInvisible