NSHTÖU
  • VDE Certification
  • EAC Certification
  • Robust
  • UKCA Certification
  • reelable
  • oil resistant
Buy items

Technical Data

Reelable control and connection cable acc. to DIN VDE 0250-814
Temperature range flexible -25°C to +80°C
fixed -40°C to +80°C
Nominal voltage AC U0/U 600/1000 V
Max. permissible operating voltage alternating current (AC) conductor/ground 700 V
three-phase alternating current (AC) conductor/conductor 1200 V
direct current (DC) conductor/ground 900 V
direct current (DC) conductor/conductor 1800 V
Test voltage conductor/conductor 2500 V
Tensile stress during installation and operation, 15 N/mm²
Minimum bend radius flexible
≤ 20 mm: 5x Outer ø
> 20 mm: 6x Outer ø

Details

Cable Structure

      • Copper conductor tinned, finely stranded acc. to DIN VDE 0295 Class 5 / IEC 60228 Class 5
      • Conductor insulation: rubber acc. to DIN VDE 0207-20 (compound type 3GI3)
      • Conductor identification acc. to DIN VDE 0293-308,
      • 3 - 5 conductor(s): color coded
      • 7 - 50 conductor(s): black conductors with consecutive white numbers
      • G = with GN-YE ground, in the outer layer
      • Conductors stranded in layers with optimal lay lengths
      • Textile bandage
      • Inner jacket: rubber
      • Anti-torsion protective layer
      • Outer jacket: rubber acc. to DIN VDE 0207-21 (compound type 5GM3)
      • Jacket color: black

Properties

      • resistant to: oil, ozone, solvents, petrol, acids, chemicals, greases
      • abrasion-resistant
      • for outdoor use
      • reeling application operating parameters
      • acceleration (max.): 0.4 m/s²
      • velocity (max.): 120 m/min
      • for horizontal reeling operations

Tests

      • flame-retardant acc. to DIN VDE 0482-332-1-2 / DIN EN 60332-1-2 / IEC 60332-1-2
      • oil-resistant acc. to DIN VDE 0473-811-404 / DIN EN 60811-404 / IEC 60811-404
      • certifications and approvals:
      • EAC

Notes

      • the conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only
      • for use in reeling applications:
      • 1) the assembly instructions must be observed
      • 2) for special applications, we recommend that you contact us and complete our reeling cables inquiry form

Application

      • Reeling cables are used for applications involving high mechanical stress, especially for applications requiring frequent winding and unwinding with simultaneous tensile and torsional stress; for construction machinery, conveying and lifting equipment and crane systems. For use as a robust and weather resistant cable in roughest operations such as mobile transport equipment, railway engines and in mining. Suitable for installation in dry, damp and wet rooms as well as outdoors.

Items NSHTÖU

No. of Conductors
Cross Section (mm²)
Outer Diameter
Conductor Identification
Item description
Part no.
AWG (approx.) Outer Ø mm (approx.) Cu factor per km Weight kg/km (approx.)