HELUPOWER® 1100-RZ1-K LS0H GREEN
  • AENOR Certification
  • Halogen-free (LS0H)
  • UV-resistant
  • Length Marking In Meters
  • UKCA Certification
  • flexible
  • direct burial
  • low smoke development
  • flame-retardant
Buy items

Technical Data

Connection cable acc. to UNE 21123-4
Temperature range flexible 0°C to +90°C
fixed -15°C to +90°C
Conductor operating temperature +90°C
Short circuit temperature at the conductor +250°C (Short circuit duration max. 5 s)
Nominal voltage AC U0/U 600/1000 V
Max. permissible operating voltage alternating current (AC) conductor/ground 700 V
three-phase alternating current (AC) conductor/conductor 1200 V
direct current (DC) conductor/ground 900 V
direct current (DC) conductor/conductor 1800 V
Test voltage conductor/conductor 3500 V
Minimum bend radius <25 mm: 4x Outer ø
25-50 mm: 5x Outer ø
>50 mm: 6x Outer ø

Details

Cable Structure

      • Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 / IEC 60228 Class 5
      • Conductor insulation: XLPE acc. to UNE-HD 603-1 (compound type DIX 3)
      • Conductor identification acc. to DIN VDE 0293-308,
      • 1 conductor(s): black
      • 2 - 5 conductor(s): color coded
      • Ground conductor: starting with 3 conductors,
      • G = with GN-YE ground,
      • x = without ground conductor
      • Conductors stranded with optimal lay lengths
      • Outer jacket: Polyolefin acc. to UNE 21123-4 (compound type DMZ-E)
      • Jacket color: green
      • Length marking: in meters

Properties

      • resistant to: oil, UV radiation
      • for outdoor use
      • direct burial
      • halogen-free
      • reduced fire propagation, reduced release of corrosive and toxic gases

Tests

      • halogen-free acc. to DIN VDE 0482-754-1 / DIN EN 60754-1 / IEC 60754-1
      • combustible gas corrosiveness acc. to DIN VDE 0482-754-2 / DIN EN 60754-2 / IEC 60754-2
      • flame-retardant acc. to DIN VDE 0482-332-1-2 / DIN EN 60332-1-2 / IEC 60332-1-2
      • bundle fire test acc. to DIN VDE 0482-332-3-24 / DIN EN 60332-3-24 / IEC 60332-3-24 (Cat. C)
      • smoke density acc. to DIN VDE 0482-1034-1+2 / DIN EN 61034-1+2 / IEC 61034-1+2
      • oil-resistant acc. to DIN VDE 0473-811-404 / DIN EN 60811-404 / IEC 60811-404
      • UV-resistant acc. to UNE 211605
      • CPR class: Cca s1b d1 a1

Notes

      • the conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only

Application

      • Suitable for fixed power supply installations in public and commercial buildings or in power distribution networks where a high degree of safety is required. Suitable for indoor and outdoor use, for laying in tubes and pipes and suitable for direct burial.

Items HELUPOWER® 1100-RZ1-K LS0H GREEN

No. of Conductors
Cross Section (mm²)
Protective Conductor (GN-YE)
Outer Diameter
Item description
Part no.
AWG (approx.) Outer Ø mm (approx.) Cu factor per km Weight kg/km (approx.)

Downloads

Info Circlechevron-leftAlertBrowse fileDownload fileFileImagePdfWordTextExcelPowerpointArchiveCsvAudioVideoSpinnerCalendarSort NoneSort ASCSort DESCReturn arrowMinusYouTubeSyncVisibleInvisible