H05VV-F/SJT
- Multi-standard connection cable
- 300 V
Technical Data H05VV-F/SJT
PVC connection cable acc. to DIN VDE 0285-525-2-11 / DIN EN 50525-2-11, UL Std. 62, CSA Std. C22.2 No. 49 | |
Temperature range | HAR flexible -5°C to +70°C HAR fixed -40°C to +70°C UL/CSA (SJT) flexible -5°C to +60°C UL/CSA (SJT) fixed -40°C to +60°C |
Nominal voltage | AC U0/U 300/500 V UL/CSA AC 300 V |
Test voltage | 2500 V |
Test voltage (spark test) | 6000 V |
Breakdown voltage | 5000 V |
Minimum bend radius | fixed 7.5x Outer Ø |
Details H05VV-F/SJT
Cable Structure
-
- Copper wire bare, finely stranded, AWG sizes
-
- Conductor insulation: Special-PVC acc. to DIN VDE 0207-363-3 / DIN EN 50363-3 (compound type TI2), UL Std. 62, CSA Std. C22.2 No. 49
-
- Conductor identification acc. to DIN VDE 0293-308, color coded
-
- Ground conductor: starting with 3 conductors,
- G = with GN-YE ground,
- x = without ground conductor
-
- Conductors stranded with optimal lay lengths
-
- Outer jacket: PVC acc. to DIN VDE 0207-363-4-1 / DIN EN 50363-4-1 (compound type TM2), UL Std. 62, CSA Std. C22.2 No. 49
-
- Jacket color: see datasheet
Properties
-
- the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers
Tests
-
- flame-retardant acc. to DIN VDE 0482-332-1-2 / DIN EN 60332-1-2 / IEC 60332-1-2, CSA FT2
-
- certifications and approvals:
- HAR
- EAC
Notes
-
- Conductor sizes are based on the AWG measurement system, metric conductor sizes (mm²) are approximated and are for reference only
Application
-
- This HAR, UL and CSA standardised, flexible PVC cable can be used in particular in appliances intended for export. For medium mechanical stress for use in households and offices, including damp rooms; including household appliances such as refrigerators, hoovers and washing machines.
Items H05VV-F/SJT
Item description
Part no.
|
Jacket color | Cross-sec. mm² (approx.) | Outer Ø mm (approx.) | Cu factor per km |
---|