TOPSERV® 600 VFD orange 4 G 8 AWG Part No. 62621
  • UL Certification
  • CSA Certification
  • EAC Certification
  • UV-resistant
  • Suitable For Drag Chains
  • Length Marking In Feet
  • UKCA Certification
  • Oil Res I/II
  • exposed run: TC-ER, PLTC-ER, ITC-ER, NFPA 79
  • EMC-preferred type

Item Details

Part No.
62621
Item description
TOPSERV® 600 VFD orange 4 G 8 AWG
Jacket color
orange (RAL 2003)
Cross-sec. mm² (approx.)
8.37
Outer Ø mm (approx.)
23.2
Cu factor per km
393.0
Weight kg/km (approx.)
796.0
Weight lb(s)/feet (approx.)
1754.9
Copper base in EUR / 100 kg
150
Feet per Packaging Unit
1640, 3280
Cut-to-length service available
yes
EAN/GTIN
4060892147142
Customs tariff number
85444995

Technical Data

Motor and servo cable acc. to UL Std. 1277 (TC-ER), UL Std. 2277 (WTTC), CSA Std. C22.2 No. 210 - AWM I/II A/B, CSA Std. C22.2 No. 230 & 239 - c(UL) CIC-TC, UL Std. 2250 (ITC-ER), UL Std. 13 (PLTC-ER), 18 AWG - 12 AWG: UL Std. 2250 (ITC-ER), UL Std. 13 (PLTC-ER), 14 AWG - 2 AWG: UL Std. 44 (RHW-2)
Temperature range flexible +5°C to +50°C
fixed -40°C to +105°C
UL (TC) to +90°C
Nominal voltage UL (TC) AC 600 V
UL (WTTC) AC 1000 V
CIC-TC AC 600 V
Test voltage conductor/conductor 6000 V
Test voltage conductor/shield 6000 V
Minimum bend radius flexible 10x Outer Ø
fixed 5x Outer Ø

Details

Cable Structure

      • Copper wire tinned, finely stranded acc. to ASTM B174 Class M (18-10 AWG) / ASTM B174 Class K (8-2 AWG), AWG sizes
      • Conductor insulation: XLPE
      • Conductor identification: black conductors with consecutive white numbers
      • G = with GN-YE ground, in the outer layer
      • Conductors stranded in layers with optimally matched lay lengths
      • Fleece wrap
      • Shield: tinned copper braided shield, approx. coverage 85%
      • Fleece wrap
      • Outer jacket: Special TPE
      • Jacket color: see datasheet
      • Length marking: in feet

Properties

      • resistant to: oil, UV radiation (SUN RES)
      • for outdoor use
      • direct burial (DIR BUR)
      • suitable for use in drag chains

Tests

      • oil-resistant acc. to UL Std 1277 Tab. 12.2, Oil Res I / Oil Res II
      • Cold Bend Test acc. to UL Std. 1277 No. 17
      • Impact Test (-ER) acc. to UL Std. 1277 No. 23
      • Crushing Test (-ER) acc. to UL Std. 1277 No. 24
      • direct burial (DIR BUR) acc. to UL Std. 1277 No. 5 (wet-locations insulation), No. 19 (crushing test)
      • Vertical-Tray Flame Test (FT4) acc. to UL Std. 1277 No. 15 / UL Std. 1685
      • certifications and approvals:
      • EAC
      • ECOLAB®
      • for Class 1 Div. 2 explosive environments acc. to NEC Art. 501

Notes

      • Conductor sizes are based on the AWG measurement system, metric conductor sizes (mm²) are approximated and are for reference only
      • for use in drag chain systems:
      • 1) the assembly instructions must be observed
      • 2) for special applications, we recommend contacting us and using our drag chain system inquiry form

Application

      • Highly flexible, extremely oil-resistant motor supply cable for modern servomotors; the tinned copper braid screen (approx. 85% coverage) provides effective protection against electrical disturbances and the resultant failures. For open, unprotected installation in cable trays and from cable trays to the machine. The special TPE sheath is extremly resistant to oil, coolants and solvents and hence the perfect solution for industrial applications with open installation, installation in pipes or in earth.
Info Circlechevron-leftAlertBrowse fileDownload fileFileImagePdfWordTextExcelPowerpointArchiveCsvAudioVideoSpinnerCalendarSort NoneSort ASCSort DESCReturn arrowMinusYouTubeSyncVisibleInvisible