HELUCOM® PROFInet B I-V4Y(ZN)Y
All items

Technical Data

Temperature range Laying, min.: -10°C
Laying, max.: +50°C
Operating, min.: -30°C
Operating, max.: +70°C

Details

Cable Structure

      • Fibre type: POF 980/1000
      • Fibre cladding: PA

Properties

      • Refractive index core: 1,492
      • Refractive index cladding: 1,419
      • Numerical aperture: 0,5
      • Attenuation see table

Application

      • Signal wire as plastic optical fibre. The use of these transmission systems significantly reduces the number of different cables in a planned bus installation in machine tools operations. Furthermore, possible EMC problems are prevented by the metal-free construction. The main fields of these cables are in machine construction and automobile industry. Installations for example in fixed installed rough areas (type B) or in drag chains (type C) are possible. The types on this page are especially constructed for communication within PROFInet systems.

Items HELUCOM® PROFInet B I-V4Y(ZN)Y

Outer diameter
Item description
Part no.
No. of fibres Fibre Type Fibre Category No. of fibres per core

Downloads