HELUDATA® 20276 PE/PVC-TP 30 GREY
  • UL certification
  • Length marking in metres
All items

Technical Data

PVC data cable acc. to UL-Std. 758 (AWM) Style 20276
Temperature range fixed -20°C to +60°C
Peak operating voltage 30 V (not for high power current installation purposes)
Test voltage core/core 1000 V
Mutual capacitance core/core at 800 Hz, approx. 115 pF/m
Mutual capacitance core/screen at 800 Hz, approx. 203 pF/m
Characteristic impedance 45 Ohm,
(approx. value)
Inductance approx. 0.55 mH/km
Minimum bending radius fixed 15x Outer-Ø

Details

Cable Structure

      • Copper wire tinned, stranded, AWG sizes
      • Core insulation: PE
      • Core identification: colour coded, pairs:
      • No. 1: black / red
      • No. 2: green / white
      • No. 3: yellow / blue
      • No. 4: pink / grey
      • x = without protective conductor
      • Cores stranded in pairs with optimal lay lengths
      • Screening element: pairs, plastic-coated aluminium foil (St)
      • Pairs stranded with optimal lay lengths
      • Drain wire, tinned copper
      • Outer sheath: PVC
      • Sheath colour: grey (RAL 7005)
      • Length marking: in metres

Properties

      • the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers

Tests

      • flame-retardant acc. to DIN VDE 0482-332-1-2 / DIN EN 60332-1-2 / IEC 60332-1-2, UL VW-1

Application

      • UL-approved data cable for wiring data processing systems; for fixed installation in dry or damp environments.

Items HELUDATA® 20276 PE/PVC-TP 30 GREY

No. of cores
No. of pairs
Outer diameter
Item description
Part no.
Outer Ø mm (approx.) Cu factor per km Weight kg/km (approx.) Copper base in EUR / 100 kg
Info Circlechevron-leftAlertBrowse fileDownload fileFileImagePdfWordTextExcelPowerpointArchiveCsvAudioVideoSpinnerCalendarSort NoneSort ASCSort DESCReturn arrowMinusYouTubeSyncVisibleInvisible