HSK-EX-Active
  • Certificat CSA
  • Sans halogène (LS0H)
  • Certificat UKCA
Tous les articles

Caractéristiques techniques

PA EX cable gland
Temperature range -20°C to +85°C
Protection class IP 68 - 10 bar

Détails du produit

Construction

      • Material: Polyamide (PA) V0 acc. to UL 94, Fibreglass reinforced
      • Seal: Nitrile butadiene rubber (NBR)
      • O-ring: Nitrile butadiene rubber (NBR)

Propriétés

      • halogen-free
      • phosphor-free
      • silicone-free
      • cadmium-free
      • optimum strain relief through clamping lamella
      • easy to assemble, time and cost savings
      • watertight, dust-tight
      • large clamping areas

Tests

      • Test standard EN 60079-0:2012, EN 60079-7:2007, EN 60079-31:2011, IEC 60079-0:2011, IEC 60079-7:2007, IEC 60079-31:2013

Remarques

      • EC-Type Examination Certificate: BVS 14 ATEX E 025 X
      • IECEx Certificate of Conformity: IECEx BVS 14.0020X
      • Marking: II 2G Ex e IIC Gb, II 1D Ex ta IIIC Da
      • Also available in blue, for the intrinsically safe area, on request.
      • Legend:
      • Dimensions
      • TD - Thread Diameter
      • TL - Thread Length
      • SZ - Spanner Size
      • H - Height

Utilisation

    • Machine and plant construction<br />• Robotics<br />• Automation technology<br />• Vehicle construction and shipbuilding<br />• Railway technology<br />• Installation technology<br />• Control cabinet construction