TOPFLEX®-EMV-UV-3-PLUS-2XSLCYK-J black 3 x 95 + 3 G 16 mm²

TOPFLEX®-EMV-UV-3-PLUS-2XSLCYK-J black 3 x 95 + 3 G 16 mm² Part No. 24518
  • EAC Certification
  • UV-resistant
  • Length Marking In Meters
  • UKCA Certification
  • +90°C Conductor Temp. Rating / Enhanced Current Carrying Capacity
  • double shielded
  • for outdoor use
  • improved EMC properties due to protective conductor (GN-YE) divided into thirds
  • 3x16 + 3G2.5 mm² and larger: suitable for direct burial

Item Details

Part No.
24518
Item description
TOPFLEX®-EMV-UV-3-PLUS-2XSLCYK-J black 3 x 95 + 3 G 16 mm²
AWG (approx.)
3/0
Outer Ø mm (approx.)
37.8
Cu factor per km
3953.0
Weight kg/km (approx.)
4008.0
Weight lb(s)/feet (approx.)
8836.2
Copper base in EUR / 100 kg
150
Feet per Packaging Unit
1640, 3280
Cut-to-length service available
yes
EAN/GTIN
4060892150968
Customs tariff number
85444995

Technical Data

Motor connection cable for frequency converters in alignment with DIN VDE 0250
Temperature range flexible -5°C to +90°C
fixed -40°C to +90°C
Conductor operating temperature +90°C
Nominal voltage AC U0/U 600/1000 V
Max. permissible operating voltage alternating current (AC) conductor/ground 700 V
three-phase alternating current (AC) conductor/conductor 1200 V
direct current (DC) conductor/ground 900 V
direct current (DC) conductor/conductor 1800 V
Test voltage conductor/conductor 4000 V
Coupling resistance see datasheet
Minimum bend radius flexing <12 mm: 10x Outer ø
flexing >12 mm: 15x Outer ø
fixed 4x Outer ø

Details

Cable Structure

      • Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 / IEC 60228 Class 5
      • Conductor insulation: XLPE
      • Conductor identification: brown, black, gray, green-yellow (divided into thirds)
      • Ground conductor: GN-YE divided into thirds (3+3 conductor structure)
      • Conductors stranded with optimal lay lengths
      • 1. Shield: plastic-coated aluminum foil (St)
      • 2. Shield: tinned copper braided shield, approx. coverage 85%
      • Outer jacket: Special-PVC
      • Jacket color: black (RAL 9005)
      • Length marking: in meters

Properties

      • resistant to: UV radiation
      • for outdoor use
      • optimal shielding enables interference-free operation of frequency converters
      • low coupling resistance ensures good electromagnetic compatibility
      • low mutual capacitance of the individual conductors due to XLPE conductor insulation and low shield capacity, enable low power transmission loss

Tests

      • flame-retardant acc. to DIN VDE 0482-332-1-2 / DIN EN 60332-1-2 / IEC 60332-1-2
      • electromagnetic compatibility acc. to DIN VDE 0875-11 / DIN EN 55011
      • minimum cross section of 0.75 mm² meets requirements acc. to DIN EN 60204-1
      • certifications and approvals:
      • EAC

Notes

      • the conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only

Application

      • Used as a connecting cable for medium mechanical stress with fixed installation and occasional free movement in dry, damp or wet rooms, as well as outdoors; direct burial installation is possible beginning with 3x16+3G2.5 mm². As a result of the permissible operating temperature of +90°C at the conductor, an enhanced current carrying capacity compared to PE insulated motor connection cables is permissible. Used in automotive, food, packaging and chemical industries, as well as in the environmental technology sector. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding.