TOPFLEX®-EMV-UV-2YSLC11Y-J UL/CSA black 4 G 50 mm²
Part No. 22397
- halogen-free
- UV resistant
- double shielded
- EMC-preferred type
Item Details TOPFLEX®-EMV-UV-2YSLC11Y-J UL/CSA black 4 G 50 mm²
- Part No.
- 22397
- Item description
- TOPFLEX®-EMV-UV-2YSLC11Y-J UL/CSA black 4 G 50 mm²
- AWG (approx.)
- 1
- Outer Ø mm (approx.)
- 35.5
- Cu factor per km
- 2345.0
- Weight kg/km (approx.)
- 2950.0
- Weight lb(s)/feet (approx.)
- 6503.7
- Copper base in EUR / 100 kg
- 150
- Feet per Packaging Unit
- 1640, 3280
- Cut-to-length service available
- yes
- EAN/GTIN
- 4060892150074
- Customs tariff number
- 85444995
Technical Data TOPFLEX®-EMV-UV-2YSLC11Y-J UL/CSA black 4 G 50 mm²
Motor connection cable for frequency converters acc. to UL Std. 758 (AWM) Style 20234, in alignment with DIN VDE 0250 | |
Temperature range | flexible -5°C to +80°C fixed -40°C to +80°C |
Nominal voltage | UL (AWM) AC 1000 V |
Test voltage conductor/conductor | 4000 V |
Mutual capacitance | see datasheet |
Coupling resistance | see datasheet |
Minimum bend radius | flexible <12 mm: 10x Outer ø 12-20 mm: 15x Outer ø >20 mm: 20x Outer ø fixed <12 mm: 5x Outer ø 12-20 mm: 7.5x Outer ø >20 mm: 10x Outer ø |
Details TOPFLEX®-EMV-UV-2YSLC11Y-J UL/CSA black 4 G 50 mm²
Cable Structure
-
- Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 / IEC 60228 Class 5
-
- Conductor insulation: PE
-
- Conductor identification: brown, black, gray, green-yellow
-
- G = with GN-YE ground
-
- Conductors stranded with optimal lay lengths
-
- 1. Shield: plastic-coated aluminum foil (St)
- 2. Shield: tinned copper braided shield, approx. coverage 85%
-
- Outer jacket: PUR
-
- Jacket color: black (RAL 9005)
-
- Length marking: in meters
Properties
-
- resistant to: oil, UV radiation, ozone, oxygen, weathering effects, hydrolysis, microbes, coolants, hydraulic fluids, acids, alkalis, greases, seawater and wastewater
-
- highly abrasion-resistant, notch-resistant, tear-resistant, cut-resistant, wear-resistant, low adhesion
-
- for outdoor use
-
- halogen-free
-
- optimal shielding enables interference-free operation of frequency converters
-
- low coupling resistance ensures good electromagnetic compatibility
-
- low mutual capacitance of the individual conductors due to PE conductor insulation and low shield capacity, enable low power transmission loss
Tests
-
- flame-retardant acc. to DIN VDE 0482-332-1-2 / DIN EN 60332-1-2 / IEC 60332-1-2, CSA FT1
-
- electromagnetic compatibility acc. to DIN VDE 0875-11 / DIN EN 55011
-
- certifications and approvals:
- EAC
Notes
-
- the conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only
Application
-
- Motor connection cable for frequency converters; secures EMC in systems and buildings with devices and machineries, which can emit electromagnetic interference fields that can impact the environment in an illegal manner. To be used as a connection cable involving medium mechanical stress for fixed installations and applications with occasional free movement in dry, moist and wet rooms and outside. For use in the automotive, food processing and packaging industry, in machine tools, handling equipment, pumps, fans, and transport belts. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding.