SOLARFLEX®-X H1Z2Z2-K NTS RED 1 x 4 mm²

SOLARFLEX®-X H1Z2Z2-K NTS RED 1 x 4 mm² Part No. 11022803
  • Halogen-free (LS0H)
  • UV-resistant
  • UKCA Certification
  • cable for photovoltaic systems
  • 1500 V DC
  • with rodent protection

Item Details

Part No.
11022803
Item description
SOLARFLEX®-X H1Z2Z2-K NTS RED 1 x 4 mm²
Jacket color
red
AWG (approx.)
12
Outer Ø mm (approx.)
5.9 - 6.6
Cu factor per km
38.4
Weight kg/km (approx.)
85.0
Weight lb(s)/feet (approx.)
187.4
Copper base in EUR / 100 kg
150
CPR class
Dca, Eca
Feet per Packaging Unit
-
Cut-to-length service available
yes
EAN/GTIN
4060892535840
Customs tariff number
85446010

Technical Data

Cross-linked single conductor cable in alignment with DIN VDE 0283-618 / DIN EN 50618
Temperature range fixed -40°C to +90°C
Conductor operating temperature +120°C
Nominal voltage AC U0/U 1000/1000 V
DC U0/U 1500/1500 V
Test voltage 6500 V
Minimum bend radius fixed 5x Outer Ø

Details

Cable Structure

      • Copper wire tinned, finely stranded acc. to DIN VDE 0295 Class 5 / IEC 60228 Class 5
      • Conductor insulation: cross-linked compound
      • x = without ground conductor
      • Outer jacket: cross-linked compound
      • Jacket color: see datasheet
      • Stainless steel braiding (V2A)

Properties

      • resistant to: UV radiation, ozone, weathering effects
      • for outdoor use
      • halogen-free

Tests

      • halogen-free acc. to DIN VDE 0482-754-1 / DIN EN 60754-1 / IEC 60754-1
      • flame-retardant acc. to DIN VDE 0482-332-1-2 / DIN EN 60332-1-2 / IEC 60332-1-2
      • smoke density acc. to DIN VDE 0482-1034-1+2 / DIN EN 61034-1+2 / IEC 61034-1+2
      • UV-resistant acc. to DIN VDE 0283-618 / DIN EN 50618 Appendix E
      • ozone-resistant acc. to DIN VDE 0283-618 / DIN EN 50618
      • weather-resistant acc. to DIN VDE 0283-618 / DIN EN 50618 Appendix E
      • DC Voltage insulation resistance acc. to DIN VDE 0283-618 / DIN EN 50618 Tab. 2

Notes

      • the conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only

Application

      • SOLARFLEX®-X H1Z2Z2-K NTS is used for wiring solar modules. The maximum permissible DC voltage of the system in which the cable is installed must not exceed 1.8 kV. The cable is suitable for use in and on devices and systems with protective insulation (protection class II). Basic version H1Z2Z2-K according to DIN EN 50618 / TÜV.
Info Circlechevron-leftAlertBrowse fileDownload fileFileImagePdfWordTextExcelPowerpointArchiveCsvAudioVideoSpinnerCalendarSort NoneSort ASCSort DESCReturn arrowMinusYouTubeSyncVisibleInvisible