RE-2Y(St)Yv BLACK 1 x 2 x 0.75 mm²
Part No. 20149
- Computer cable
- reinforced outer jacket
- with drain wire
- Suitable for outdoor use (for static installations)
- with blue outer jacket: for intrinsically safe systems in explosion-endangered areas
Item Details RE-2Y(St)Yv BLACK 1 x 2 x 0.75 mm²
- Part No.
- 20149
- Item description
- RE-2Y(St)Yv BLACK 1 x 2 x 0.75 mm²
- Jacket color
- black (RAL 9005)
- AWG (approx.)
- 19
- Outer Ø mm (approx.)
- 7.7
- Cu factor per km
- 20.0
- Weight kg/km (approx.)
- 74.0
- Weight lb(s)/feet (approx.)
- 163.1
- Copper base in EUR / 100 kg
- 100
- CPR class
- Eca
- Feet per Packaging Unit
- 328, 1640, 3280
- Cut-to-length service available
- yes
- EAN/GTIN
- 4060892100710
- Customs tariff number
- 85444995
Technical Data RE-2Y(St)Yv BLACK 1 x 2 x 0.75 mm²
Computer cable in alignment with DIN VDE 0819-7 / DIN EN 50288-7 | |
Temperature range | flexible -5°C to +50°C fixed -40°C to +70°C |
Peak operating voltage | 300 V (not for high power current installation purposes) |
Test voltage conductor/conductor | 2000 V |
Test voltage conductor/shield | 1000 V |
Conductor resistance at 20°C | 0.5 mm²: max. 39.2 Ohm/km 0.75 mm²: max. 24.6 Ohm/km 1.3 mm²: max. 14.2 Ohm/km |
Crosstalk attenuation | at 60 kHz, 0.88 dB (approx. value) |
Inductance | approx. 0.75 mH/km |
Minimum bend radius | flexible 15x Outer Ø fixed 7.5x Outer Ø |
Details RE-2Y(St)Yv BLACK 1 x 2 x 0.75 mm²
Cable Structure
-
- Copper wire bare, stranded
-
- Wire structure:
- 0.5 mm²: 7 x 0.3 mm
- 0.75 mm²: 7 x 0.37 mm
- 1.3 mm²: 7 x 0.49 mm
-
- Conductor insulation: PE
-
- Conductor identification: color coded, pairs:
- conductor a = black; conductor b = white
- with consecutive numbering 1/1, 2/2, etc.,
- triads: conductor a = black; conductor b = white; conductor c = red
-
- Conductors stranded in pairs/triads with optimal lay lengths, Pairs stranded in layers with optimal lay lengths
-
- for multiple pair design: communication conductor, nominal cross section: 0.5 mm², Conductor insulation: PE, Conductor identification: orange
-
- Foil wrap
-
- Drain wire, tinned copper, stranded (0.5 mm² = 7 x 0.3 mm)
-
- Shield: plastic-coated aluminum foil (St), approx. overlap 25%
-
- Outer jacket: PVC, reinforced (v)
-
- Jacket color: see datasheet
-
- Length marking: in meters
Properties
-
- for outdoor use
-
- direct burial
-
- low attenuation and operating capacities allow long transmission distances and short pulse transition times
Tests
-
- flame-retardant acc. to DIN VDE 0482-332-1-2 / DIN EN 60332-1-2 / IEC 60332-1-2
-
- certifications and approvals:
- EAC
Notes
-
- the conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only
-
- copper weight including communication conductor and stranded copper drain wire
-
- with blue jacket for installation in intrinsically safe systems (ignition protection type -i-) in explosion-endangered areas according to DIN VDE 0165-1 / DIN EN 60079-14 / IEC 60079-14, Section 16.2.2
Application
-
- Computer cables are used in data processing and process control. When permanently installed, suitable for use in dry and damp rooms, outdoors and underground.