RD-Y(St)YY gray 4 x 2 x 0.5 mm²
Part No. 20181
- Data transmission cable
- double outer jacket
- for outdoor use
- direct burial
Item Details RD-Y(St)YY gray 4 x 2 x 0.5 mm²
- Part No.
- 20181
- Item description
- RD-Y(St)YY gray 4 x 2 x 0.5 mm²
- AWG (approx.)
- 20
- Outer Ø mm (approx.)
- 10.3
- Cu factor per km
- 45.0
- Weight kg/km (approx.)
- 139.0
- Copper base in EUR / 100 kg
- 100
- CPR class
- Eca
- Feet per Packaging Unit
- 328, 1640, 3280
- Cut-to-length service available
- yes
- EAN/GTIN
- 4060892100444
- Customs tariff number
- 85444995
Technical Data RD-Y(St)YY gray 4 x 2 x 0.5 mm²
PVC data cable in alignment with DIN VDE 0815 | |
Temperature range | flexible -5°C to +50°C fixed -30°C to +70°C |
Peak operating voltage | 600 V (not for high power current installation purposes) |
Test voltage conductor/conductor | 2000 V |
Test voltage conductor/shield | 2000 V |
Conductor resistance at 20°C | max. 39.2 Ohm/km |
Mutual capacitance conductor/conductor | at 800 Hz 2 - 4 pairs: approx. 120 pF/m 8 - 96 pairs: approx. 100 pF/m |
Capacitive coupling k1 | at 800 Hz, max. 200 pF/100m; 20% of the values, but at least one value may amount up to 400 pF/100m |
Characteristic impedance | at 1 kHz, 370 Ohm, at 10 kHz, 130 Ohm, (approx. value) |
Cable attenuation | at 1 kHz, 1.2 dB/km at 10 kHz, 3.0 dB/km (approx. value) |
Crosstalk attenuation | at 10 kHz, 60.00 dB (approx. value) |
Minimum bend radius | flexible 10x Outer Ø fixed 10x Outer Ø |
Details RD-Y(St)YY gray 4 x 2 x 0.5 mm²
Cable Structure
-
- Copper wire bare, stranded
-
- Wire structure:
- 0.5 mm²: 7 x 0.3 mm
-
- Conductor insulation: semirigid PVC
-
- Conductor identification: color coded, per bundle:
- Pair No. 1: conductor a = blue; conductor b = red
- Pair No. 2: conductor a = gray; conductor b = yellow
- Pair No. 3: conductor a = green; conductor b = brown
- Pair No. 4: conductor a = white; conductor b = black
-
- Conductors stranded in pairs with optimal lay lengths, 4 pairs stranded into bundles with optimal lay lengths, bundles stranded in layers with optimal lay lengths
-
- Bundle identification: synthetic helix with printed digits
-
- Drain wire, tinned copper, stranded (0.5 mm² = 7 x 0.3 mm)
-
- Shield: plastic-coated aluminum foil (St), approx. overlap 25%
-
- Outer jacket: PVC, double (YY)
-
- Jacket color: gray (RAL 7032)
-
- Length marking: in meters
Properties
-
- direct burial
-
- pair stranding with short and varied lay lengths within a bundle, leads to good crosstalk attenuation values
Tests
-
- flame-retardant acc. to DIN VDE 0482-332-1-2 / DIN EN 60332-1-2 / IEC 60332-1-2
-
- certifications and approvals:
- EAC
Notes
-
- the conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only
-
- 2-pair cables: conductors stranded in a star quad
Application
-
- RD data transmission cables are used in measurement and control technology, as well as in control stations of industrial plants. The cables are used for the transmission of analogue and digital signals up to a frequency of approximately 10 kHz. They are suitable for fixed installations inside buildings, outdoors and underground.