PUR-C-PUR gray 4 G 0.75 mm²
Part No. 22317
- oil resistant PUR conductor insulation & PUR outer jacket
- highly abrasion-resistant
- notch, cut and wear resistant
- EMC-preferred type
- without an inner jacket
- for outdoor use
- robust control and connection cable for high mechanical stress in machine, tool and plant construction
Item Details PUR-C-PUR gray 4 G 0.75 mm²
- Part No.
- 22317
- Item description
- PUR-C-PUR gray 4 G 0.75 mm²
- AWG (approx.)
- 19
- Outer Ø mm (approx.)
- 8
- Cu factor per km
- 60.0
- Weight kg/km (approx.)
- 95.0
- Weight lb(s)/feet (approx.)
- 209.4
- Copper base in EUR / 100 kg
- 150
- Feet per Packaging Unit
- 328, 1640, 3280
- Cut-to-length service available
- yes
- EAN/GTIN
- 4060892079870
- Customs tariff number
- 85444995
Technical Data PUR-C-PUR gray 4 G 0.75 mm²
PUR control cable in alignment with DIN VDE 0285-525-1 / DIN EN 50525-1 | |
Temperature range | fixed -40°C to +80°C |
Nominal voltage | 0.75 - 1 mm²: AC U0/U 300/500 V 1.5 - 2.5 mm²: AC U0/U 450/750 V |
Test voltage conductor/conductor | 2000 V |
Mutual capacitance conductor/conductor | at 800 Hz, approx. 150 pF/m |
Mutual capacitance conductor/shield | at 800 Hz, approx. 320 pF/m |
Coupling resistance | at 30 MHz, approx. 250 Ohm/km |
Minimum bend radius | flexible 10x Outer Ø fixed 5x Outer Ø |
Details PUR-C-PUR gray 4 G 0.75 mm²
Cable Structure
-
- Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 / IEC 60228 Class 5
-
- Conductor insulation: Special-PUR
-
- Conductor identification acc. to DIN VDE 0293-308,
- 2 - 5 conductor(s): color coded
- 6 conductor(s): black conductors with consecutive white numbers
-
- Ground conductor: starting with 3 conductors,
- G = with GN-YE ground,
- x = without ground conductor
-
- Conductors stranded with optimal lay lengths
-
- Foil wrap
-
- Shield: tinned copper braided shield, approx. coverage 85%
-
- Outer jacket: Special grade of full polyurethane acc. to DIN VDE 0207-363-10-2 / DIN EN 50363-10-2 (compound type TMPU)
-
- Jacket color: gray (RAL 7032)
-
- Length marking: in meters
Properties
-
- resistant to: oil, UV radiation, ozone, oxygen, weathering effects, hydrolysis, microbes, coolants, hydraulic fluids, acids, alkalis, greases, seawater and wastewater
-
- highly abrasion-resistant, notch-resistant, tear-resistant, cut-resistant, wear-resistant, low adhesion
-
- for outdoor use
-
- flexible in cold temperatures
-
- halogen-free
Tests
-
- oil-resistant acc. to DIN VDE 0473-811-404 / DIN EN 60811-404 / IEC 60811-404
-
- UV-resistant acc. to DIN EN ISO 4892-2
-
- weather-resistant acc. to DIN EN ISO 4892-2
-
- certifications and approvals:
- EAC
Notes
-
- the conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only
Application
-
- Cable with copper shielding to prevent electromagnetic interference; particularly suitable as a data transfer and connection cable in machine and vehicle construction. Due to its mechanical, thermal and chemical properties, it has also proven itself under adverse weather and environmental conditions. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding.