(N)YM(St)-J gray 5 G 1.5 re mm²
Part No. 43052
- PVC Installation cable
- shielded
Item Details (N)YM(St)-J gray 5 G 1.5 re mm²
- Part No.
- 43052
- Item description
- (N)YM(St)-J gray 5 G 1.5 re mm²
- AWG (approx.)
- 16
- Outer Ø mm (approx.)
- 12
- Cu factor per km
- 87.0
- Weight kg/km (approx.)
- 208.0
- Weight lb(s)/feet (approx.)
- 458.6
- Copper base in EUR / 100 kg
- 150
- CPR class
- Eca
- Feet per Packaging Unit
- 328, 1640, 3280
- Cut-to-length service available
- yes
- EAN/GTIN
- 4060892259715
- Customs tariff number
- 85444995
Technical Data (N)YM(St)-J gray 5 G 1.5 re mm²
PVC Installation cable in alignment with DIN VDE 0250-204 | |
Temperature range | fixed -40°C to +70°C during installation +5°C to +70°C |
Conductor operating temperature | +70°C |
Nominal voltage | AC U0/U 300/500 V |
Test voltage conductor/conductor | 2000 V |
Minimum bend radius | fixed 4x Outer Ø |
Details (N)YM(St)-J gray 5 G 1.5 re mm²
Cable Structure
-
- Copper conductor bare, 1.5 - 10 mm²: solid acc. to DIN VDE 0295 Class 1 / IEC 60228 Class 1; 16 - 25 mm²: stranded acc. to DIN VDE 0295 Class 2 / IEC 60228 Class 2
-
- Conductor insulation: PVC acc. to DIN VDE 0207-363-3 / DIN EN 50363-3 (compound type TI1)
-
- Conductor identification acc. to DIN VDE 0293-308,
- 3 - 5 conductor(s): color coded
- 7 conductor(s): black conductors with consecutive white numbers
-
- G = with GN-YE ground
-
- Conductors stranded in layers with optimal lay lengths
-
- drain wire, tinned copper, solid
-
- Shield: plastic-coated aluminum foil (St)
-
- Outer jacket: PVC acc. to DIN VDE 0207-363-4-1 / DIN EN 50363-4-1 (compound type TM1)
-
- Jacket color: gray (RAL 7035)
Tests
-
- flame-retardant acc. to DIN VDE 0482-332-1-2 / DIN EN 60332-1-2 / IEC 60332-1-2
-
- certifications and approvals:
- EAC
Notes
-
- re = round, solid conductor
- rm = round, stranded conductor
-
- the conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only
Application
-
- Installation cable with static screen, designed for the effective limitation of electromagnetic interference fields. The design proves to be advantageous for installation in the computer sector, in hospitals, in industrial control rooms with interference-sensitive devices as well as in living areas of people that are extremely sensitive to radiation. Suitable for installation in dry, damp or wet environments; for installation above, on, in and under plaster as well as in masonry walls and in concrete, however not for direct embedding in vibration, compacted or tamped concrete. Suitable for outdoor installation as long as the cable is protected against direct sunlight.