NSHXAFÖ 1,8/3 kV black 1 x 2.5 mm² Part No. 38518
  • VDE Certification
  • Halogen-free (LS0H)
  • UKCA Certification
  • short-circuit and ground-fault proof up to 1000 V
  • oil resistant
  • for increased mechanical stress

Item Details

Part No.
38518
Item description
NSHXAFÖ 1,8/3 kV black 1 x 2.5 mm²
AWG (approx.)
14
Cu factor per km
24.0
Weight kg/km (approx.)
76.0
Weight lb(s)/feet (approx.)
167.6
Copper base in EUR / 100 kg
150
CPR class
Eca
Feet per Packaging Unit
328, 1640, 3280
Cut-to-length service available
yes
EAN/GTIN
4060892258398
Customs tariff number
85446010

Technical Data

Rubber-jacketed, single-conductor cable acc. to E DIN VDE 0250-606
Temperature range flexible -25°C to +70°C
fixed -40°C to +90°C
Conductor operating temperature +90°C
Nominal voltage AC U0/U 1800/3000 V
Max. permissible operating voltage alternating current (AC) conductor/ground 2100 V
three-phase alternating current (AC) conductor/conductor 3600 V
direct current (DC) conductor/ground 2700 V
direct current (DC) conductor/conductor 5400 V
Test voltage 6000 V
Minimum bend radius flexible 10x Outer Ø
fixed 6x Outer Ø

Details

Cable Structure

      • Copper wire tinned, finely stranded acc. to DIN VDE 0295 Class 5 / IEC 60228 Class 5
      • Conductor insulation: rubber (EPR) acc. to DIN VDE 0207-20 (compound type 3GI3)
      • x = without ground conductor
      • Outer cladding: halogen-free polymer acc. to DIN VDE 0207-24 (compound type HM3)
      • Color: black

Properties

      • resistant to: oil
      • halogen-free

Tests

      • combustible gas corrosiveness acc. to DIN VDE 0482-754-2 / DIN EN 60754-2 / IEC 60754-2
      • flame-retardant acc. to DIN VDE 0482-332-1-2 / DIN EN 60332-1-2 / IEC 60332-1-2
      • smoke density acc. to DIN VDE 0482-1034-1+2 / DIN EN 61034-1+2 / IEC 61034-1+2
      • oil-resistant acc. to DIN VDE 0473-811-404 / DIN EN 60811-404 / IEC 60811-404

Notes

      • the conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only

Application

      • For use in rail vehicles and buses, as well as in dry rooms. The cable is short-circuit and earth-fault proof in switchgear and distribution boards up to 1000 V. Normative permissible laying types are: in pipes, closed installation ducts, for connecting moving parts, device wiring and bundled. Not for use on cable ladders and cable trays.
Info Circlechevron-leftAlertBrowse fileDownload fileFileImagePdfWordTextExcelPowerpointArchiveCsvAudioVideoSpinnerCalendarSort NoneSort ASCSort DESCReturn arrowMinusYouTubeSyncVisibleInvisible