HELUWIND® WK POWERLINE ALU ROBUST 0,6/1 kV black 1 x 185 mm²

HELUWIND® WK POWERLINE ALU ROBUST 0,6/1 kV black 1 x 185 mm² Part No. 707101
  • UV-resistant
  • Robust
  • UKCA Certification
  • highly abrasion-resistant
  • PUR outer jacket with high mechanical strength
  • finely stranded Al wire, extremely flexible
  • low weight
  • recyclable
  • oil and UV resistant
  • certified connection components available

Item Details

Part No.
707101
Item description
HELUWIND® WK POWERLINE ALU ROBUST 0,6/1 kV black 1 x 185 mm²
AWG (approx.)
350 kcmil
Outer Ø mm (approx.)
24.3
Al factor per km
544.0
Weight kg/km (approx.)
790.0
Weight lb(s)/feet (approx.)
1741.7
Aluminum base in EUR / 100 kg
0
Feet per Packaging Unit
1640, 3280
Cut-to-length service available
yes
EAN/GTIN
4060892330322
Customs tariff number
85444995

Technical Data

Jacketed single conductor cable in alignment with DIN VDE 0250-813
Temperature range flexible -20°C to +90°C
fixed -40°C to +90°C
Conductor operating temperature +90°C
Nominal voltage AC U0/U 600/1000 V
Test voltage conductor/conductor 4000 V
Minimum bend radius flexible 10x Outer Ø
fixed 4x Outer Ø

Details

Cable Structure

      • Al wire, finely stranded
      • Conductor insulation: Special-PVC
      • Conductor identification: black
      • x = without ground conductor
      • Outer jacket: Special-PUR
      • Jacket color: black

Properties

      • resistant to: oil, UV radiation
      • highly abrasion-resistant, notch-resistant, tear-resistant, cut-resistant, wear-resistant, low adhesion
      • excellent flexibility enables fast installation
      • recyclable

Tests

      • flame-retardant acc. to DIN VDE 0482-332-1-2 / DIN EN 60332-1-2 / IEC 60332-1-2

Notes

      • the conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only
      • Further details, as well as information regarding custom solutions and suitable connection technology, can be found by contacting wind@helukabel.de.

Application

      • Extremely flexible aluminium cable for use in many areas of energy and plant engineering. The high flexibility and low dead weight can significantly reduce labour time required for installation in the field. Due to the sheathing material used, the HELUWIND® WK POWERLINE ALU ROBUST is extremely resistant to abrasion and mechanical stress. It may only be handled using the certified HELUKABEL® C8 crimping method according to IEC 61238-1 Class A. The appropriate tools for this connection method are available for delivery (may also be rented).

Downloads

Info Circlechevron-leftAlertBrowse fileDownload fileFileImagePdfWordTextExcelPowerpointArchiveCsvAudioVideoSpinnerCalendarSort NoneSort ASCSort DESCReturn arrowMinusYouTubeSyncVisibleInvisible