HELUPOWER® SOOW black 7 x 14 AWG Part No. 11161407
  • UL Certification
  • CSA Certification
  • UV-resistant
  • Robust
  • heavy rubber cable
  • oil resistant
  • 600 V
  • +90°C

Item Details

Part No.
11161407
Item description
HELUPOWER® SOOW black 7 x 14 AWG
Outer Ø mm (approx.)
17.2 - 19.2
Cu factor per km
139.8
Weight kg/km (approx.)
456.0
Weight lb(s)/feet (approx.)
1005.3
Copper base in EUR / 100 kg
150
Feet per Packaging Unit
-
Cut-to-length service available
yes
EAN/GTIN
4060892543005
Customs tariff number
85444995

Technical Data

Rubber control and connection cable acc. to UL Std. 62, CSA Std. C22.2 No. 49
Temperature range flexible -20°C to +90°C
fixed -40°C to +90°C
Conductor operating temperature +90°C
Nominal voltage AC U 600 V
Test voltage conductor/conductor 2500 V
Minimum bend radius flexible 10x Outer Ø
fixed 6x Outer Ø

Details

Cable Structure

      • Copper wire bare, finely stranded, AWG sizes
      • Conductor insulation: rubber (EPR)
      • Conductor identification:
      • 2 conductor(s): black, white
      • 3 conductor(s): black, white, green
      • 4 conductor(s): black, white, red, green
      • 5 conductor(s): black, white, red, green, orange
      • 6 conductor(s): black, white, red, green, orange, blue
      • 7 conductor(s): black, white, red, green, orange, blue, white-black
      • 8 conductor(s): black, white, red, green, orange, blue, white-black, red-black
      • 12 conductor(s): black, white, red, green, orange, blue, white-black, red-black, green-black, orange-black, blue-black, black-white
      • 16 conductor(s): black, white, red, green, orange, blue, white-black, red-black, green-black, orange-black, blue-black, black-white, red-white, green-white, blue-white, black-red
      • x = without ground conductor
      • Conductors stranded in layers with optimal lay lengths
      • Wrapping
      • Outer jacket: rubber (CPE)
      • Jacket color: black

Properties

      • resistant to: oil, ozone, weathering effects, greases, water, UV radiation (SUN RES)
      • for outdoor use

Tests

      • flame-retardant acc. to CSA FT2
      • certifications and approvals:
      • Mine Safety and Health Administration (MSHA), U.S. Department of Labor
      • for Class 1 Div. 2 explosive environments acc. to NEC Art. 501

Application

      • Standardised, heavy, rubber-sheathed cable for usage in dry, moist, wet rooms as well as outdoors. Used as supply cable in industrial plants and processing facilities, for cranes, hand lamps, lifting devices, construction machinery and motors.
Info Circlechevron-leftAlertBrowse fileDownload fileFileImagePdfWordTextExcelPowerpointArchiveCsvAudioVideoSpinnerCalendarSort NoneSort ASCSort DESCReturn arrowMinusYouTubeSyncVisibleInvisible