HELUPOWER® 1000 RV-K black 3 G 2.5 mm²
Part No. 11003824
- direct burial
- XLPE conductor insulation / 90°C
Item Details HELUPOWER® 1000 RV-K black 3 G 2.5 mm²
- Part No.
- 11003824
- Item description
- HELUPOWER® 1000 RV-K black 3 G 2.5 mm²
- AWG (approx.)
- 14
- Outer Ø mm (approx.)
- 9.8 - 10.5
- Cu factor per km
- 72.0
- Weight kg/km (approx.)
- 210.0
- Weight lb(s)/feet (approx.)
- 463.0
- Copper base in EUR / 100 kg
- 150
- CPR class
- Eca
- Feet per Packaging Unit
- 328, 1640, 3280
- Cut-to-length service available
- yes
- EAN/GTIN
- 4060892008931
- Customs tariff number
- 85444995
Technical Data HELUPOWER® 1000 RV-K black 3 G 2.5 mm²
PVC connection cable, acc. to UNE 21123-2; articles with 3+1/2 conductors: in alignment with UNE 21123-2 | |
Temperature range | fixed -15°C to +90°C |
Conductor operating temperature | +90°C |
Short circuit temperature at the conductor | +250°C (Short circuit duration max. 5 s) |
Nominal voltage | AC U0/U 600/1000 V |
Max. permissible operating voltage | alternating current (AC) conductor/ground 700 V three-phase alternating current (AC) conductor/conductor 1200 V direct current (DC) conductor/ground 900 V direct current (DC) conductor/conductor 1800 V |
Test voltage conductor/conductor | 3500 V |
Minimum bend radius | <25 mm: 4x Outer ø 25-50 mm: 5x Outer ø >50 mm: 6x Outer ø |
Details HELUPOWER® 1000 RV-K black 3 G 2.5 mm²
Cable Structure
-
- Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 / IEC 60228 Class 5
-
- Conductor insulation: XLPE acc. to UNE-HD 603-1 (compound type DIX 3)
-
- Conductor identification: see datasheet
-
- G = with GN-YE ground, in the outer layer,
- x = without ground conductor
-
- Conductors stranded in layers with optimal lay lengths
-
- Outer jacket: PVC acc. to UNE HD 603-1 (compound type DMV 18)
-
- Jacket color: black
-
- Length marking: in meters
Properties
-
- resistant to: UV radiation
-
- for outdoor use
-
- direct burial
Tests
-
- flame-retardant acc. to DIN VDE 0482-332-1-2 / DIN EN 60332-1-2 / IEC 60332-1-2
-
- UV-resistant acc. to DIN VDE 0276-605 / HD 605 S2
Notes
-
- the conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only
Application
-
- Suitable for use in dry, moist and wet rooms as well as outdoors. Also suitable for direct burial, laying in tubes and underground installation areas. Typical application areas range from general production machinery, to machine tool applications, conveyor belt systems, air-conditioning units, steel plants installations and factory automation. Ideal as power or control cable especially if increased temperature and/or voltage is required. UV resistant due to it's special PVC outer sheath compound and therefore also ideal as power connection cable for outdoor devices and machinery. Alternatively also for use as power connection cable in the stage and lighting industry or renewable energy sector.