HELUDATA® JE-LiYCY Bd PVC GREY 2 x 2 x 0.5 mm² Part No. 48510
  • EAC Certification
  • UKCA Certification
  • Cables for Industrial Electronics
  • stranded conductor
  • with blue outer jacket: for intrinsically safe systems in explosion-endangered areas

Item Details

Part No.
48510
Item description
HELUDATA® JE-LiYCY Bd PVC GREY 2 x 2 x 0.5 mm²
Jacket color
gray (RAL 7032)
AWG (approx.)
20
Outer Ø mm (approx.)
7
Cu factor per km
51.0
Weight kg/km (approx.)
94.0
Weight lb(s)/feet (approx.)
207.2
Copper base in EUR / 100 kg
100
CPR class
Eca
Feet per Packaging Unit
328, 1640, 3280
Cut-to-length service available
yes
EAN/GTIN
4060892097003
Customs tariff number
85444995

Technical Data

PVC data cable in alignment with DIN VDE 0815
Temperature range flexible -5°C to +50°C
fixed -30°C to +70°C
Peak operating voltage 225 V (not for high power current installation purposes)
Test voltage conductor/conductor 500 V
Test voltage conductor/shield 2000 V
Conductor resistance at 20°C max. 39.2 Ohm/km
Mutual capacitance conductor/conductor at 800 Hz
2 - 4 pairs: approx. 120 pF/m
8 - 40 pairs: approx. 100 pF/m
Capacitive coupling k1 at 800 Hz, max. 200 pF/100m
Cable attenuation at 800 Hz, 1.1 dB/km
(approx. value)
Inductance approx. 0.70 mH/km
Minimum bend radius fixed 6x Outer Ø

Details

Cable Structure

      • Copper wire bare, stranded
      • Wire structure:
      • 0.5 mm²: 7 x 0.3 mm
      • Conductor insulation: semirigid PVC
      • Conductor identification acc. to. DIN VDE 0815, color coded
      • Conductors stranded in pairs with optimal lay lengths, 4 pairs stranded into bundles with optimal lay lengths, bundles stranded in layers with optimal lay lengths
      • Foil wrap
      • Shield: bare or tinned copper braided shield, approx. coverage 85%
      • Outer jacket: PVC acc. to DIN VDE 0207-5 (compound type YM1)
      • Jacket color: see datasheet

Properties

      • the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers

Tests

      • flame-retardant acc. to DIN VDE 0482-332-1-2 / DIN EN 60332-1-2 / IEC 60332-1-2

Notes

      • the conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only
      • 2-pair cables: conductors stranded in a star quad
      • with blue jacket for installation in intrinsically safe systems (ignition protection type -i-) in explosion-endangered areas according to DIN VDE 0165-1 / DIN EN 60079-14 / IEC 60079-14, Section 16.2.2

Application

      • The cables are used for the transmission of signals and measurements in symmetrical circuits for control technology, as well as for the transmission of information in data and process computer systems. They can be used in dry and damp operating areas, as well as in and under plaster and outdoors with fixed installation. Installation cables are not permitted for high voltage current installations or underground laying. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding.
Info Circlechevron-leftAlertBrowse fileDownload fileFileImagePdfWordTextExcelPowerpointArchiveCsvAudioVideoSpinnerCalendarSort NoneSort ASCSort DESCReturn arrowMinusYouTubeSyncVisibleInvisible