YELLOWFLEX yellow 12 G 1.5 mm² Part No. 37268
  • EAC Certification
  • Robust
  • Length Marking In Meters
  • UKCA Certification
  • Rubber connection cable
  • weather-resistant
  • for outdoor use
  • for high mechanical stress
  • custom printing possible

Item Details

Part No.
37268
Item description
YELLOWFLEX yellow 12 G 1.5 mm²
AWG (approx.)
16
Outer Ø mm (approx.)
17.6 - 22.4
Cu factor per km
175.0
Weight kg/km (approx.)
460.0
Weight lb(s)/feet (approx.)
1014.1
Copper base in EUR / 100 kg
150
Feet per Packaging Unit
1640, 3280
Cut-to-length service available
yes
EAN/GTIN
4060892167195
Customs tariff number
85444995

Technical Data

Rubber connection cable in alignment with DIN VDE 0285-525-2-21 / DIN EN 50525-2-21
Temperature range flexible -25°C to +60°C
fixed -30°C to +60°C
Conductor operating temperature +60°C
Nominal voltage AC U0/U 450/750 V
Max. permissible operating voltage alternating current (AC) conductor/ground 476 V
three-phase alternating current (AC) conductor/conductor 825 V
direct current (DC) conductor/ground 619 V
direct current (DC) conductor/conductor 1238 V
Test voltage conductor/conductor 2500 V
Tensile stress during installation and operation, 15 N/mm²
Minimum bend radius fixed 4x Outer Ø
flexing, guide roll 7.5x Outer Ø
flexing, drum winding 5x Outer Ø

Details

Cable Structure

      • Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 / IEC 60228 Class 5
      • Conductor insulation: rubber acc. to DIN VDE 0207-363-1 / DIN EN 50363-1 (compound type EI4)
      • Conductor identification acc. to DIN VDE 0293-308,
      • 2 - 5 conductor(s): color coded
      • 7 - 12 conductor(s): black conductors with consecutive white numbers
      • Ground conductor: starting with 3 conductors,
      • G = with GN-YE ground, in the outer layer,
      • x = without ground conductor
      • Conductors stranded in layers with optimal lay lengths
      • Outer jacket: rubber acc. to DIN VDE 0207-363-2-1 / DIN EN 50363-2-1 (compound type EM2)
      • Jacket color: yellow (RAL 1021)
      • Length marking: in meters

Properties

      • resistant to: weathering effects
      • largely resistant to: oil, greases
      • tear-resistant, wear-resistant
      • for outdoor use

Tests

      • flame-retardant acc. to DIN VDE 0482-332-1-2 / DIN EN 60332-1-2 / IEC 60332-1-2
      • certifications and approvals:
      • EAC

Notes

      • the conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only
      • please contact us for outer jacket custom printing

Application

      • Robust rubber cable for applications that require extreme flexibility and where cables are subject to high mechanical loads. For use in dry, damp and wet rooms as well as outdoors such as in metallurgical plants and rolling mills, in heating and air conditioning technology, in the bottling industry, in machinery and plant engineering, in the chemical industry as well as in the craft and hobby sector. The yellow colour of the sheath is used for safety. When laid in pipes or in similar closed systems, the use of the cable is permitted up to and including 1000 V AC or 750 V DC against earth.
Info Circlechevron-leftAlertBrowse fileDownload fileFileImagePdfWordTextExcelPowerpointArchiveCsvAudioVideoSpinnerCalendarSort NoneSort ASCSort DESCReturn arrowMinusYouTubeSyncVisibleInvisible