TOPSERV® 600 VFD orange 4 G 10 AWG
Part No. 62620
- Oil Res I/II
- exposed run: TC-ER, PLTC-ER, ITC-ER, NFPA 79
- EMC-preferred type
Item Details TOPSERV® 600 VFD orange 4 G 10 AWG
- Part No.
- 62620
- Item description
- TOPSERV® 600 VFD orange 4 G 10 AWG
- Jacket color
- orange (RAL 2003)
- Cross-sec. mm² (approx.)
- 5.26
- Outer Ø mm (approx.)
- 18
- Cu factor per km
- 239.0
- Weight kg/km (approx.)
- 484.0
- Weight lb(s)/feet (approx.)
- 1067.0
- Copper base in EUR / 100 kg
- 150
- Feet per Packaging Unit
- 1640, 3280
- Cut-to-length service available
- yes
- EAN/GTIN
- 4060892147135
- Customs tariff number
- 85444995
Technical Data TOPSERV® 600 VFD orange 4 G 10 AWG
Motor and servo cable acc. to UL Std. 1277 (TC-ER), UL Std. 2277 (WTTC), CSA Std. C22.2 No. 210 - AWM I/II A/B, CSA Std. C22.2 No. 230 & 239 - c(UL) CIC-TC, UL Std. 2250 (ITC-ER), UL Std. 13 (PLTC-ER), 18 AWG - 12 AWG: UL Std. 2250 (ITC-ER), UL Std. 13 (PLTC-ER), 14 AWG - 2 AWG: UL Std. 44 (RHW-2) | |
Temperature range | flexible +5°C to +50°C fixed -40°C to +105°C UL (TC) to +90°C |
Nominal voltage | UL (TC) AC 600 V UL (WTTC) AC 1000 V CIC-TC AC 600 V |
Test voltage conductor/conductor | 6000 V |
Test voltage conductor/shield | 6000 V |
Minimum bend radius | flexible 10x Outer Ø fixed 5x Outer Ø |
Details TOPSERV® 600 VFD orange 4 G 10 AWG
Cable Structure
-
- Copper wire tinned, finely stranded acc. to ASTM B174 Class M (18-10 AWG) / ASTM B174 Class K (8-2 AWG), AWG sizes
-
- Conductor insulation: XLPE
-
- Conductor identification: black conductors with consecutive white numbers
-
- G = with GN-YE ground, in the outer layer
-
- Conductors stranded in layers with optimally matched lay lengths
-
- Fleece wrap
-
- Shield: tinned copper braided shield, approx. coverage 85%
-
- Fleece wrap
-
- Outer jacket: Special TPE
-
- Jacket color: see datasheet
-
- Length marking: in feet
Properties
-
- resistant to: oil, UV radiation (SUN RES)
-
- for outdoor use
-
- direct burial (DIR BUR)
-
- suitable for use in drag chains
Tests
-
- oil-resistant acc. to UL Std 1277 Tab. 12.2, Oil Res I / Oil Res II
-
- Cold Bend Test acc. to UL Std. 1277 No. 17
-
- Impact Test (-ER) acc. to UL Std. 1277 No. 23
-
- Crushing Test (-ER) acc. to UL Std. 1277 No. 24
-
- direct burial (DIR BUR) acc. to UL Std. 1277 No. 5 (wet-locations insulation), No. 19 (crushing test)
-
- Vertical-Tray Flame Test (FT4) acc. to UL Std. 1277 No. 15 / UL Std. 1685
-
- certifications and approvals:
- EAC
- ECOLAB®
- for Class 1 Div. 2 explosive environments acc. to NEC Art. 501
Notes
-
- Conductor sizes are based on the AWG measurement system, metric conductor sizes (mm²) are approximated and are for reference only
-
- for use in drag chain systems:
- 1) the assembly instructions must be observed
- 2) for special applications, we recommend contacting us and using our drag chain system inquiry form
Application
-
- Highly flexible, extremely oil-resistant motor supply cable for modern servomotors; the tinned copper braid screen (approx. 85% coverage) provides effective protection against electrical disturbances and the resultant failures. For open, unprotected installation in cable trays and from cable trays to the machine. The special TPE sheath is extremly resistant to oil, coolants and solvents and hence the perfect solution for industrial applications with open installation, installation in pipes or in earth.