Single 600-J black 1 G 120 mm² Part No. 10897
  • UL Certification
  • CSA Certification
  • EAC Certification
  • UV-resistant
  • Length Marking In Meters
  • UKCA Certification
  • PVC-jacketed single conductor cable
  • 600 V

Item Details

Part No.
10897
Item description
Single 600-J black 1 G 120 mm²
AWG (approx.)
4/0
Outer Ø mm (approx.)
22.3
Cu factor per km
1152.0
Weight kg/km (approx.)
1545.0
Weight lb(s)/feet (approx.)
3406.2
Copper base in EUR / 100 kg
150
Feet per Packaging Unit
1640, 3280
Cut-to-length service available
yes
EAN/GTIN
4060892172502
Customs tariff number
85444995

Technical Data

PVC-jacketed single conductor cable acc. to UL Std. 758 (AWM) Style 10107, CSA Std. C22.2 No. 210 - AWM I/II A/B, in alignment with DIN VDE 0285-525-2-31 / DIN EN 50525-2-31
Temperature range flexible -5°C to +90°C
fixed -40°C to +90°C
Conductor operating temperature +90°C
Nominal voltage VDE AC U0/U 600/1000 V
UL (AWM) AC 600 V
Test voltage 4000 V
Breakdown voltage 8000 V
Minimum bend radius flexible 7.5x Outer Ø
fixed 4x Outer Ø

Details

Cable Structure

      • Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 / IEC 60228 Class 5
      • Conductor insulation: Special-PVC acc. to UL Std. 1581
      • Conductor identification: see datasheet
      • G = with GN-YE ground,
      • x = without ground conductor
      • Outer jacket: PVC acc. to DIN VDE 0207-5 (compound type YM5), UL Std. 1581
      • Jacket color: black (RAL 9005)
      • Length marking: in meters

Properties

      • resistant to: UV radiation
      • largely resistant to: oil,
      • for details, see "Technical Information"
      • for outdoor use

Tests

      • flame-retardant acc. to DIN VDE 0482-332-1-2 / DIN EN 60332-1-2 / IEC 60332-1-2, UL VW-1, CSA FT1
      • certifications and approvals:
      • EAC

Notes

      • the conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only

Application

      • PVC sheathed single core cable suitable for medium mechanical stress with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, as well as outdoors. May not be laid directly in soil or water. This two-standard sheathed single core cables are preferably used in export-oriented mechanical engineering on machine tools, production lines and in plant construction.