PAAR-TRONIC-Li-2YCYv black 10 x 2 x 1 mm² Part No. 21150
  • HAR Certification
  • product.icon.logo_dnv
  • VDE Certification
  • EAC Certification
  • UV-resistant
  • Length Marking In Meters
  • UKCA Certification
  • low capacitance
  • reinforced outer jacket
  • with drain wire
  • Suitable for outdoor use (for static installations)
  • direct burial
  • EMC-preferred type

Item Details

Part No.
21150
Item description
PAAR-TRONIC-Li-2YCYv black 10 x 2 x 1 mm²
AWG (approx.)
18
Outer Ø mm (approx.)
20
Cu factor per km
282.0
Weight kg/km (approx.)
387.0
Copper base in EUR / 100 kg
150
Feet per Packaging Unit
1640, 3280
Cut-to-length service available
yes
EAN/GTIN
4060892097874
Customs tariff number
85444995

Technical Data

PVC data cable
Temperature range flexible -5°C to +70°C
fixed -30°C to +80°C
Peak operating voltage 250 V (not for high power current installation purposes)
Test voltage conductor/conductor 2000 V
Test voltage conductor/shield 1000 V
Conductor resistance at 20°C 0.22 mm²: max. 93.0 Ohm/km
0.34 mm²: max. 57.5 Ohm/km
0.5 mm²: max. 39.3 Ohm/km
1 mm²: max. 19.6 Ohm/km
Mutual capacitance conductor/conductor at 800 Hz
2 - 4 pairs: approx. 72 pF/m
8 - 10 pairs: approx. 60 pF/m
Crosstalk attenuation at 1 MHz, 50.00 dB
at 10 MHz, 40.00 dB
(approx. value)
Inductance approx. 0.66 mH/km
Coupling resistance at 30 MHz, approx. 250 Ohm/km
Minimum bend radius flexible 12x Outer Ø
fixed 7.5x Outer Ø

Details

Cable Structure

      • Copper wire bare, stranded
      • Wire structure:
      • 0.22 mm²: 7 x 0.2 mm
      • 0.34 mm²: 7 x 0.25 mm
      • 0.5 mm²: 7 x 0.3 mm
      • 1 mm²: 7 x 0.42 mm
      • Conductor insulation: PE acc. to DIN VDE 0819-103 / DIN EN 50290-2-23 (compound type LD/MD)
      • Conductor identification acc. to DIN 47100 (paired stranding), color coded
      • x = without ground conductor
      • Conductors stranded in pairs with optimal lay lengths, Pairs stranded in layers with optimal lay lengths
      • Foil wrap
      • Drain wire, tinned copper
      • Shield: tinned copper braided shield, approx. coverage 85%
      • Outer jacket: PVC acc. to DIN VDE 0207-363-4-1 / DIN EN 50363-4-1 (compound type TM2), reinforced (v)
      • Jacket color: black (RAL 9005)
      • Length marking: in meters

Properties

      • resistant to: UV radiation, weathering effects
      • for outdoor use
      • direct burial

Tests

      • flame-retardant acc. to DIN VDE 0482-332-1-2 / DIN EN 60332-1-2 / IEC 60332-1-2
      • UV-resistant acc. to DIN EN ISO 4892-2
      • weather-resistant acc. to DIN EN ISO 4892-2
      • certifications and approvals:
      • EAC

Notes

      • the conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only

Application

      • PE-insulated data cable with twisted pairs, for interference-free transmission of data and signals over longer distances. The twisted-pair lay-up prevents electrical unbalances within the cable and this thus effectively suppresses cross-talking effects. The high transmission rates are particularly suitable for RS 422 and RS 485 interfaces; suitable for fixed installations in dry, damp and wet rooms, as well as outdoors and direct burial. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding.
Info Circlechevron-leftAlertBrowse fileDownload fileFileImagePdfWordTextExcelPowerpointArchiveCsvAudioVideoSpinnerCalendarSort NoneSort ASCSort DESCReturn arrowMinusYouTubeSyncVisibleInvisible