JB-750 gray 4 G 35 mm²
Part No. 11138
- color coded
- largely oil resistant
- versatile use in many industries, particularly in machine building and plant engineering
Item Details JB-750 gray 4 G 35 mm²
- Part No.
- 11138
- Item description
- JB-750 gray 4 G 35 mm²
- AWG (approx.)
- 2
- Outer Ø mm (approx.)
- 30
- Cu factor per km
- 1344.0
- Weight kg/km (approx.)
- 2105.0
- Weight lb(s)/feet (approx.)
- 4640.8
- Copper base in EUR / 100 kg
- 150
- CPR class
- Eca
- Feet per Packaging Unit
- 1640, 3280
- Cut-to-length service available
- yes
- EAN/GTIN
- 4060892006784
- Customs tariff number
- 85444995
Technical Data JB-750 gray 4 G 35 mm²
PVC control and connection cable in alignment with DIN VDE 0285-525-2-11 / DIN EN 50525-2-11 | |
Temperature range | flexible -15°C to +80°C fixed -40°C to +80°C |
Nominal voltage | AC U0/U 450/750 V static and protected installation AC U0/U 600/1000 V |
Test voltage conductor/conductor | 4000 V |
Breakdown voltage | 8000 V |
Minimum bend radius | flexible 7.5x Outer Ø fixed 4x Outer Ø |
Details JB-750 gray 4 G 35 mm²
Cable Structure
-
- Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 / IEC 60228 Class 5
-
- Conductor insulation: PVC acc. to DIN VDE 0207-363-3 / DIN EN 50363-3 (compound type TI2)
-
- Conductor identification acc. to JB/OB color code, color coded
-
- Ground conductor: starting with 3 conductors,
- G = with GN-YE ground, in the outer layer,
- X = without ground conductor (OB)
-
- Conductors stranded in layers with optimal lay lengths
-
- Outer jacket: PVC acc. to DIN VDE 0207-363-4-1 / DIN EN 50363-4-1 (compound type TM2)
-
- Jacket color: gray (RAL 7001)
-
- Length marking: in meters
Properties
-
- largely resistant to: oil,
- for details, see "Technical Information"
Tests
-
- flame-retardant acc. to DIN VDE 0482-332-1-2 / DIN EN 60332-1-2 / IEC 60332-1-2
-
- certifications and approvals:
- EAC
Notes
-
- the conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only
-
- cleanroom qualification tested on analog types; please note "cleanroom qualification" in your order
Application
-
- Used for flexible applications involving medium mechanical stress with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use as a connection and control cable in machine tools, assembly lines, conveyor belts, production lines, plant construction, heating and air-conditioning technology, power plants, smelters and steel mills.