HELUTHERM® 400 white 1 x 0.5 mm² Part No. 50905
  • HAR Certification
  • EAC Certification
  • product.icon.logo_dnv
  • VDE Certification
  • Halogen-free (LS0H)
  • UKCA Certification
  • Single conductor
  • stranded
  • nickel conductor
  • for high temperature applications

Item Details

Part No.
50905
Item description
HELUTHERM® 400 white 1 x 0.5 mm²
Conductor Color
white
AWG (approx.)
20
Outer Ø mm (approx.)
2.1 - 2.6
Ni factor per km
4.8
Nickel base in EUR / 100 kg
0
Feet per Packaging Unit
1640
Cut-to-length service available
no
EAN/GTIN
4060892245763
Customs tariff number
85444995

Technical Data

Single conductor
Temperature range fixed -60°C to +400°C
Nominal voltage AC U0/U 300/500 V
Test voltage (spark test) 2000 V
Minimum bend radius flexible 15x Outer Ø
fixed 7.5x Outer Ø

Details

Cable Structure

      • Ni conductor, stranded
      • Conductor insulation: Glass silk braid with special heat resistant saturation
      • Conductor identification: see datasheet; identification by colored helix

Properties

      • halogen-free

Tests

      • halogen-free acc. to DIN VDE 0482-754-1 / DIN EN 60754-1 / IEC 60754-1

Notes

      • the conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only

Application

      • Single core with a wide temperature range; especially suited for use in the aviation and aerospace industry, in power stations, in engine design as well as in chemical, steel and metallurgical plants. For critical applications, for example involving mechanical stress, we recommend to contact us.
Info Circlechevron-leftAlertBrowse fileDownload fileFileImagePdfWordTextExcelPowerpointArchiveCsvAudioVideoSpinnerCalendarSort NoneSort ASCSort DESCReturn arrowMinusYouTubeSyncVisibleInvisible