HELUTHERM® 145 dark blue 1 x 0.75 mm²
Part No. 51305
- temperature-resistant single conductor
- enhanced characteristics during fire conditions
- cross-linked insulation material
Item Details HELUTHERM® 145 dark blue 1 x 0.75 mm²
- Part No.
- 51305
- Item description
- HELUTHERM® 145 dark blue 1 x 0.75 mm²
- Conductor Color
- dark blue (RAL 5010)
- AWG (approx.)
- 19
- Outer Ø mm (approx.)
- 2.2
- Cu factor per km
- 7.2
- Weight kg/km (approx.)
- 11.0
- Weight lb(s)/feet (approx.)
- 24.3
- Copper base in EUR / 100 kg
- 150
- CPR class
- Dca, Eca
- Feet per Packaging Unit
- 328, 1640, 3280
- Cut-to-length service available
- no
- EAN/GTIN
- 4060892231254
- Customs tariff number
- 85444995
Technical Data HELUTHERM® 145 dark blue 1 x 0.75 mm²
Single conductor | |
Temperature range | flexible -35°C to +120°C fixed -55°C to +145°C |
Nominal voltage | 0.25 - 1 mm²: AC U0/U 300/500 V 1.5 - 240 mm²: AC U0/U 450/750 V 1.5 - 240 mm²: static and protected installation AC U0/U 600/1000 V |
Test voltage | 3500 V |
Minimum bend radius | flexible 8x Outer Ø fixed 4x Outer Ø |
Details HELUTHERM® 145 dark blue 1 x 0.75 mm²
Cable Structure
-
- Copper wire tinned, finely stranded acc. to DIN VDE 0295 Class 5 / IEC 60228 Class 5
-
- Conductor insulation: cross-linked polyolefin
-
- Conductor identification: see datasheet
Properties
-
- resistant to: oil, UV radiation, ozone, weathering effects
-
- abrasion-resistant, notch-resistant
-
- for outdoor use
-
- halogen-free
-
- no fire propagation
Tests
-
- halogen-free acc. to DIN VDE 0482-754-1 / DIN EN 60754-1 / IEC 60754-1
-
- combustible gas corrosiveness acc. to DIN VDE 0482-754-2 / DIN EN 60754-2 / IEC 60754-2
-
- flame-retardant acc. to DIN VDE 0482-332-1-2 / DIN EN 60332-1-2 / IEC 60332-1-2
-
- bundle fire test acc. to DIN VDE 0482-332-3-22 / DIN EN 60332-3-22 / IEC 60332-3-22
-
- smoke density acc. to DIN VDE 0482-1034-1+2 / DIN EN 61034-1+2 / IEC 61034-1+2
-
- protection against fire acc. to DIN EN 45545-2
-
- oil-resistant acc. to DIN VDE 0473-811-404 / DIN EN 60811-404 / IEC 60811-404, IRM 902 4h at +70°C
-
- certifications and approvals:
- EAC
- 0.5 - 240 mm²: DNV
Notes
-
- the conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only
Application
-
- Temperature resistant single core for the internal wiring of lighting fixtures, heaters, electrical machinery, switching systems and distributors in industrial equipment as well as plant and machinery construction; suitable for laying in tubes on and under plaster, in closed installation ducts, as well as for traffic systems and outdoor applications. Not suitable for direct laying in cable ladders and cable trays, except as a potential equalization cable.