HELUPOWER® THERMFLEX® 145-C black 1 x 70 mm² Part No. 17001680
  • HAR Certification
  • EAC Certification
  • product.icon.logo_dnv
  • VDE Certification
  • Halogen-free (LS0H)
  • UV-resistant
  • UKCA Certification
  • conductor stranded with optimal lay lengths
  • temperature-resistant
  • enhanced characteristics during fire conditions
  • cross-linked insulation and jacketing material
  • EMC-preferred type

Item Details

Part No.
17001680
Item description
HELUPOWER® THERMFLEX® 145-C black 1 x 70 mm²
AWG (approx.)
2/0
Outer Ø mm (approx.)
19.1
Cu factor per km
756.0
Weight kg/km (approx.)
968.0
Copper base in EUR / 100 kg
150
Feet per Packaging Unit
-
Cut-to-length service available
yes
EAN/GTIN
4060892525964
Customs tariff number
85444995

Technical Data

Jacketed single conductor cable
Temperature range flexible -40°C to +120°C
fixed -55°C to +145°C
Short circuit temperature at the conductor +250°C
Nominal voltage AC U0/U 600/1000 V
Max. permissible operating voltage alternating current (AC) conductor/ground 700 V
three-phase alternating current (AC) conductor/conductor 1200 V
direct current (DC) conductor/ground 900 V
direct current (DC) conductor/conductor 1800 V
Test voltage 4000 V
Minimum bend radius flexible 12.5x Outer Ø
fixed 4x Outer Ø

Details

Cable Structure

      • Copper wire tinned, finely stranded acc. to DIN VDE 0295 Class 5 / IEC 60228 Class 5
      • Conductor insulation: cross-linked polyolefin
      • Conductor identification: black
      • x = without ground conductor
      • Shield: tinned copper braided shield, approx. coverage 85%
      • Outer jacket: cross-linked polyolefin
      • Jacket color: black

Properties

      • resistant to: oil, UV radiation, ozone, weathering effects
      • abrasion-resistant, notch-resistant
      • for outdoor use
      • halogen-free
      • reduced fire propagation, no release of corrosive and toxic gases, low smoke development

Tests

      • halogen-free acc. to DIN VDE 0482-754-1 / DIN EN 60754-1 / IEC 60754-1
      • combustible gas corrosiveness acc. to DIN VDE 0482-754-2 / DIN EN 60754-2 / IEC 60754-2
      • bundle fire test acc. to DIN VDE 0482-332-3-22 / DIN EN 60332-3-22 / IEC 60332-3-22
      • smoke density acc. to DIN VDE 0482-1034-1+2 / DIN EN 61034-1+2 / IEC 61034-1+2
      • oil-resistant acc. to DIN VDE 0473-811-404 / DIN EN 60811-404 / IEC 60811-404, IRM 902 4h at +70°C

Notes

      • the conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only

Application

      • This cable is used as a generator connection cable in wind power plants and wherever a high current carrying capacity is required and a reduced outer diameter is beneficial due to limited installation space. Other areas of application: connection cable of thermal class B (130°C) for motors, transformers, relays, coils, magnets; power unit connections in the automotive industry; halogen-free wiring of switch and control cabinets; connecting cable for heating devices; supply cable for high-performance luminaires in industrial areas, sports facilities and traffic infrastructure; wiring of charging stations and pantographs within e-Mobility applications. EMC= Electromagnetic compatibility; to optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
Info Circlechevron-leftAlertBrowse fileDownload fileFileImagePdfWordTextExcelPowerpointArchiveCsvAudioVideoSpinnerCalendarSort NoneSort ASCSort DESCReturn arrowMinusYouTubeSyncVisibleInvisible