HELUPOWER® H07RN-F LS0H black 5 G 16 mm²

HELUPOWER® H07RN-F LS0H black 5 G 16 mm² Part No. 30802
  • HAR Certification
  • EAC Certification
  • Halogen-free (LS0H)
  • UV-resistant
  • UKCA Certification
  • halogen-free
  • oil resistant
  • for use in stagnant waters up to a water depth of 100 m

Item Details

Part No.
30802
Item description
HELUPOWER® H07RN-F LS0H black 5 G 16 mm²
AWG (approx.)
6
Outer Ø mm (approx.)
26.4 - 30.0
Cu factor per km
768.0
Weight kg/km (approx.)
1465.0
Weight lb(s)/feet (approx.)
3229.8
Copper base in EUR / 100 kg
150
CPR class
Eca
Feet per Packaging Unit
1640, 3280
Cut-to-length service available
yes
EAN/GTIN
4060892166051
Customs tariff number
85444995

Technical Data

Rubber connection cable acc. to DIN VDE 0285-525-2-21 / DIN EN 50525-2-21
Temperature range flexible -40°C to +90°C
fixed -50°C to +90°C
Conductor operating temperature +90°C
Short circuit temperature at the conductor +250°C
Nominal voltage AC U0/U 450/750 V
Max. permissible operating voltage alternating current (AC) conductor/ground 476 V
three-phase alternating current (AC) conductor/conductor 825 V
direct current (DC) conductor/ground 619 V
direct current (DC) conductor/conductor 1238 V
Test voltage conductor/conductor 2500 V
Minimum bend radius flexible 6x Outer Ø
fixed 4x Outer Ø

Details

Cable Structure

      • Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 / IEC 60228 Class 5
      • Conductor insulation: Special rubber
      • Conductor identification acc. to DIN VDE 0293-308,
      • 1 conductor(s): black
      • 2 - 5 conductor(s): color coded
      • 7 - 12 conductor(s): black conductors with consecutive white numbers
      • Ground conductor: starting with 3 conductors,
      • G = with GN-YE ground, in the outer layer,
      • x = without ground conductor
      • Conductors stranded in layers with optimal lay lengths
      • Outer jacket: Special rubber
      • Jacket color: black

Properties

      • resistant to: oil, UV radiation, ozone, weathering effects, lubricating oils, greases
      • for outdoor use
      • halogen-free

Tests

      • halogen-free acc. to DIN VDE 0482-754-1 / DIN EN 60754-1 / IEC 60754-1
      • combustible gas corrosiveness acc. to DIN VDE 0482-754-2 / DIN EN 60754-2 / IEC 60754-2
      • flame-retardant acc. to DIN VDE 0482-332-1-2 / DIN EN 60332-1-2 / IEC 60332-1-2
      • smoke density acc. to DIN VDE 0482-1034-1+2 / DIN EN 61034-1+2 / IEC 61034-1+2
      • oil-resistant acc. to DIN VDE 0473-811-404 / DIN EN 60811-404 / IEC 60811-404
      • ozone-resistant acc. to DIN VDE 0473-811-403 / DIN EN 60811-403
      • certifications and approvals:
      • HAR
      • EAC

Notes

      • the conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only

Application

      • Halogen-free rubber sheathed cables for use with medium mechanical stress in dry, damp, wet rooms and outdoors. Can only be used in stagnant waters (also in salt water) up to a water depth of 100 m (AD8) and a water temperature of min. +5°C. When installed in pipes or similar closed systems, the use of the cable is permitted up to and including 1000 V AC voltage or up to 750 V DC voltage against earth.