HELUDATA® TRONIC-CY 2464 / 300 BLACK 6 x 24 AWG
Part No. 83990
- UL Style 2464
- 300 V
- 80°C
- EMC-preferred type
Item Details HELUDATA® TRONIC-CY 2464 / 300 BLACK 6 x 24 AWG
- Part No.
- 83990
- Item description
- HELUDATA® TRONIC-CY 2464 / 300 BLACK 6 x 24 AWG
- Jacket color
- black (RAL 9005)
- Cross-sec. mm² (approx.)
- 0.23
- Outer Ø mm (approx.)
- 5.7
- Cu factor per km
- 32.8
- Weight kg/km (approx.)
- 40.0
- Weight lb(s)/feet (approx.)
- 88.2
- Copper base in EUR / 100 kg
- 150
- Feet per Packaging Unit
- 328, 1640, 3280
- Cut-to-length service available
- yes
- EAN/GTIN
- 4060892093135
- Customs tariff number
- 85444995
Technical Data HELUDATA® TRONIC-CY 2464 / 300 BLACK 6 x 24 AWG
PVC data cable acc. to UL Std. 758 (AWM) Style 2464, CSA Std. C22.2 No. 210 - AWM I/II A/B | |
Temperature range | flexible -10°C to +80°C fixed -40°C to +80°C |
Nominal voltage | UL (AWM) AC 300 V |
Test voltage conductor/conductor | 1500 V |
Breakdown voltage | 3000 V |
Coupling resistance | at 30 MHz, approx. 250 Ohm/km |
Minimum bend radius | flexible 15x Outer Ø fixed 7.5x Outer Ø |
Details HELUDATA® TRONIC-CY 2464 / 300 BLACK 6 x 24 AWG
Cable Structure
-
- Copper wire tinned, finely stranded, AWG sizes
-
- Wire structure:
- 26 AWG: 7 x 0.162 mm
- 24 AWG: 7 x 0.202 mm
- 22 AWG: 7 x 0.254 mm
- 20 AWG: 7 x 0.320 mm
- 18 AWG: 19 x 0.235 mm
- 16 AWG: 19 x 0.310 mm
-
- Conductor insulation:
- 26 - 20 AWG: semirigid PVC acc. to UL Std. 1581 Tab. 50.183
- 18 - 16 AWG: PVC acc. to UL Std. 1581 Tab. 50.182
-
- Conductor identification: see datasheet
-
- x = without ground conductor
-
- Conductors stranded in layers with optimal lay lengths
-
- Foil wrap
-
- Drain wire, tinned copper
-
- Shield: tinned copper braided shield, approx. coverage 85%
-
- Outer jacket: PVC acc. to UL Std. 1581 Tab. 50.182, CSA Std. C22.2 No. 210
-
- Jacket color: see datasheet
Properties
-
- resistant to: oil, solvents, acids, alkalis
Tests
-
- flame-retardant acc. to DIN VDE 0482-332-1-2 / DIN EN 60332-1-2 / IEC 60332-1-2, UL VW-1, CSA FT1
Notes
-
- Conductor sizes are based on the AWG measurement system, metric conductor sizes (mm²) are approximated and are for reference only
Application
-
- UL/CSA approved, flexible data cable for applications within control and regulation engineering as well as measurement, signal and impulse technology. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding.