H05RR-F black 3 G 4 mm² Part No. 35015
  • HAR Certification
  • EAC Certification
  • UKCA Certification
  • Rubber connection cable
  • for light mechanical stress

Item Details

Part No.
35015
Item description
H05RR-F black 3 G 4 mm²
AWG (approx.)
12
Outer Ø mm (approx.)
11.3 - 14.5
Cu factor per km
115.0
Weight kg/km (approx.)
260.0
Weight lb(s)/feet (approx.)
573.2
Copper base in EUR / 100 kg
150
CPR class
Eca, Fca
Feet per Packaging Unit
328, 1640, 3280
Cut-to-length service available
yes
EAN/GTIN
4060892166297
Customs tariff number
85444995

Technical Data

Rubber connection cable acc. to DIN VDE 0285-525-2-21 / DIN EN 50525-2-21
Temperature range flexible -25°C to +60°C
fixed -30°C to +60°C
Conductor operating temperature +60°C
Nominal voltage AC U0/U 300/500 V
Max. permissible operating voltage alternating current (AC) conductor/ground 318 V
three-phase alternating current (AC) conductor/conductor 550 V
direct current (DC) conductor/ground 413 V
direct current (DC) conductor/conductor 825 V
Test voltage conductor/conductor 2000 V
Minimum bend radius 7.5x Outer Ø

Details

Cable Structure

      • Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 / IEC 60228 Class 5
      • Conductor insulation: rubber acc. to DIN VDE 0207-363-1 / DIN EN 50363-1 (compound type EI4)
      • Conductor identification acc. to DIN VDE 0293-308, color coded
      • Ground conductor: starting with 3 conductors,
      • G = with GN-YE ground,
      • x = without ground conductor
      • Conductors stranded with optimal lay lengths
      • Outer jacket: rubber acc. to DIN VDE 0207-363-2-1 / DIN EN 50363-2-1 (compound type EM3)
      • Jacket color: black

Tests

      • flame-retardant acc. to DIN VDE 0482-332-1-2 / DIN EN 60332-1-2 / IEC 60332-1-2
      • certifications and approvals:
      • HAR
      • EAC

Notes

      • the conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only

Application

      • For use in dry, damp or wet rooms for connecting devices subject to low levels of mechanical stress in households, kitchens or offices (e.g. vacuum cleaners, kitchen appliances, portable household appliances, garden tools). For temporary and limited use outdoors.
Info Circlechevron-leftAlertBrowse fileDownload fileFileImagePdfWordTextExcelPowerpointArchiveCsvAudioVideoSpinnerCalendarSort NoneSort ASCSort DESCReturn arrowMinusYouTubeSyncVisibleInvisible