EDV-PiMF-CY gray 3 x 2 x 0.5 mm² Part No. 43554
  • EAC Certification
  • Length Marking In Meters
  • UKCA Certification
  • PiMF: Pair in Metal Foil
  • PE insulation
  • low capacitance
  • EMC-preferred type

Item Details

Part No.
43554
Item description
EDV-PiMF-CY gray 3 x 2 x 0.5 mm²
AWG (approx.)
20
Outer Ø mm (approx.)
10.2
Cu factor per km
66.0
Weight kg/km (approx.)
120.0
Weight lb(s)/feet (approx.)
264.6
Copper base in EUR / 100 kg
150
CPR class
Eca
Feet per Packaging Unit
328, 1640, 3280
Cut-to-length service available
yes
EAN/GTIN
4060892098185
Customs tariff number
85444995

Technical Data

PVC data cable
Temperature range flexible -5°C to +80°C
fixed -20°C to +80°C
Peak operating voltage 300 V (not for high power current installation purposes)
Test voltage conductor/conductor 2000 V
Test voltage conductor/shield 1000 V
Mutual capacitance conductor/conductor at 800 Hz, approx. 75 pF/m
Characteristic impedance at 1 kHz, 360 Ohm,
at 10 kHz, 125 Ohm,
at 100 kHz, 87 Ohm,
at 1000 kHz, 70 Ohm,
(approx. value)
Cable attenuation at 1 kHz, 1.1 dB/km
at 10 kHz, 2.7 dB/km
at 100 kHz, 6.8 dB/km
at 1000 kHz, 35.0 dB/km
(approx. value)
Crosstalk attenuation at 100 kHz, 60.00 dB
(approx. value)
Inductance approx. 0.40 mH/km
Coupling resistance at 30 MHz, approx. 250 Ohm/km
Minimum bend radius flexible 10x Outer Ø
fixed 5x Outer Ø

Details

Cable Structure

      • Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 / IEC 60228 Class 5
      • Conductor insulation: PE
      • Conductor identification acc. to DIN 47100 (paired stranding), color coded
      • x = without ground conductor
      • Conductors stranded in pairs with optimal lay lengths
      • Foil wrap of the pairs
      • Drain wire per pair, tinned copper
      • Shielding element: pairs, plastic-coated aluminum foil (St), approx. overlap 25%
      • Pairs (in metal foil) stranded in layers with optimal lay lengths
      • Foil wrap
      • Shield: tinned copper braided shield, approx. coverage 85%
      • Outer jacket: PVC in alignment with DIN VDE 0207-363-4-1 / DIN EN 50363-4-1 (compound type TM2)
      • Jacket color: gray (RAL 7032)
      • Length marking: in meters

Properties

      • PiMF: Pair in Metal Foil

Tests

      • flame-retardant acc. to DIN VDE 0482-332-1-2 / DIN EN 60332-1-2 / IEC 60332-1-2
      • certifications and approvals:
      • EAC

Notes

      • the conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only

Application

      • Used as a data cable with overall pair screening and low capacities for installed terminals in medical and data technology. Application is also suitable in tool and machine construction, rolling mills and smelters, as well as traffic and process technology. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding.
Info Circlechevron-leftAlertBrowse fileDownload fileFileImagePdfWordTextExcelPowerpointArchiveCsvAudioVideoSpinnerCalendarSort NoneSort ASCSort DESCReturn arrowMinusYouTubeSyncVisibleInvisible