HELUKAT® 100IND CAT.5 SF/UTP FRNC STATIC blue 2 x 2 x AWG 24 /1 Part no. 805699
  • Halogen-free (LS0H)
  • FRNC (Flame Retardant Non-Corrosive)
  • Length marking in metres
  • UKCA certification
  • for applications up to 100 Megabit
  • FRNC Outer sheath

Item Details

Part no.
805699
Item description
HELUKAT® 100IND CAT.5 SF/UTP FRNC STATIC blue 2 x 2 x AWG 24 /1
Cross-sec. mm² (approx.)
0.20
Conductor Ø mm (approx.)
0.51
Core Ø mm (approx.)
1.03
Outer Ø mm (approx.)
5.6
Cu-weight kg/km
22.0
Weight kg/km (approx.)
45.0
Copper base in EUR / 100 kg
150
Metres per Packaging Unit
100, 500, 1000
Cut-to-length service available
yes
EAN / GTIN
4060892314513
Customs tariff number
85444995

Technical Data

Industrial Ethernet cable / Cat. 5 acc. to ISO/IEC 11801, DIN EN 50173, IEC 61156-2, DIN EN 50288-2-1
Temperature range fixed installation -25°C to +80°C
during installation -5°C to +60°C
Peak operating voltage 125 V (not for high power current installation purposes)
Test voltage core/core 1000 V
Conductor resistance at 20°C max. 96.0 Ohm/km
Loop resistance at 20°C max. 192.0 Ohm/km
Insulation resistance min. 5.0 GOhm x km
Mutual capacitance core/core at 800 Hz, approx. 48 pF/m
Rel. Velocity of Propagation approx. 70%
Characteristic impedance at 1 to 100 MHz, 100 Ohm ± 15 Ohm
Caloric load approx. 0.43 MJ/m
Minimum bending radius during installation 15x Outer-Ø
fixed installation 8x Outer-Ø

Details

Cable Structure

      • Copper conductor bare, AWG sizes
      • Core insulation: Foam PE
      • Core identification: colour coded, pairs:
      • No. 1: white-orange / orange
      • No. 2: white-green / green
      • Cores stranded in pairs with optimal lay lengths
      • Foil wrapping
      • Pairs stranded with optimal lay lengths
      • 1. Screen: plastic-coated aluminium foil (St)
      • 2. Screen: braided screen of tinned copper wires
      • Outer sheath: halogen-free, flame retardant compound (FRNC)
      • Sheath colour: blue
      • Length marking: in metres

Properties

      • halogen-free
      • flame-retardant, low smoke development

Tests

      • halogen-free acc. to DIN VDE 0482-754-1 / DIN EN 60754-1 / IEC 60754-1
      • corrosiveness of combustion gases acc. to DIN VDE 0482-754-2 / DIN EN 60754-2 / IEC 60754-2
      • flame-retardant acc. to DIN VDE 0482-332-1-2 / DIN EN 60332-1-2 / IEC 60332-1-2

Notes

      • Conductor sizes are based on the AWG measurement system, metric conductor sizes (mm²) are approximated and are for reference only

Application

      • HELUKAT® 100IND CAT.5 SF/UTP FRNC STATIC for fixed installation indoor in halogen free and flame retardent edition.

Downloads

Info Circlechevron-leftAlertBrowse fileDownload fileFileImagePdfWordTextExcelPowerpointArchiveCsvAudioVideoSpinnerCalendarSort NoneSort ASCSort DESCReturn arrowMinusYouTubeSyncVisibleInvisible