HELUDATA® EN-50288-7 PVC/PVC OSA 500 zwart 12 x 2 x 0,75 mm²
Artikelnr. 11016624
Itemdetails HELUDATA® EN-50288-7 PVC/PVC OSA 500 zwart 12 x 2 x 0,75 mm²
- Artikelnr.
- 11016624
- Artikel omschrijving
- HELUDATA® EN-50288-7 PVC/PVC OSA 500 zwart 12 x 2 x 0,75 mm²
- Buiten-Ø mm (ongeveer)
- 21,2 - 25,9
- Cu factor per km
- 191,7
- Gewicht kg/km (ongeveer)
- 1094,0
- Koperbasis in EUR / 100 kg
- 150
- Meters per verpakkingseenheid
- 500, 1000
- individuele hoeveelheden bestelbaar
- ja
- EAN/GTIN
- 4060892443046
- Douanetariefnummer
- 85444995
Technische gegevens HELUDATA® EN-50288-7 PVC/PVC OSA 500 zwart 12 x 2 x 0,75 mm²
Instrumentation cable acc. to EN 50288-7 | |
Temperature range | flexing -5°C to +50°C fixed -30°C to +70°C |
Nominal voltage | U AC 500 V |
Test voltage core/core | 2000 V |
Test voltage core/screen | 2000 V |
Minimum bending radius | fixed 10x Outer-Ø |
Insulation resistance | > 100 MΩxkm |
Mutual capacitance | single pair max. 250 pF/m |
Inductance | max. 1 mH/km |
L/R (ratio) | 0.5 mm² < 25 μH/Ω 0.75 mm² < 25 μH/Ω 1 mm² < 25 μH/Ω 1.5 mm² < 40 μH/Ω 2.5 mm² < 60 μH/Ω |
Details HELUDATA® EN-50288-7 PVC/PVC OSA 500 zwart 12 x 2 x 0,75 mm²
Kabelopbouw
-
- Copper wire bare, stranded acc. to DIN VDE 0295 Class 2 / IEC 60228 Class 2
-
- Core insulation: PVC acc. to EN 50290-2-21
-
- Core identification:
- pairs: bu, bk
- triads: bu, bk, rd
- quads: bu, bk, rd, gy
- blue cores with consecutive labeling in black digits
-
- Cores stranded in pairs / triads / quads, cores stranded in cable elements with optimal lay lengths
-
- Cable elements are stranded with optimal lay lengths
-
- Overall screen: AL/PET tape over tinned copper stranded drain wire (7x0,3 mm)
-
- Inner sheath: PVC acc. to EN 50290-2-22
-
- Inner sheath colour: like outer sheath
-
- Armouring: single layer of galvanised round steel wires acc. to EN 10257-1
-
- Outer sheath: PVC acc. to EN 50290-2-22
-
- Outer sheath colour: black (RAL 9005) or blue (RAL 5015)
-
- Length marking: in metres
Eigenschappen
-
- low level of line attenuations and low mutual capacitances enable long transmission distances
-
- cable elements are produced of non-hygroscopic materials
Tests
-
- Sunlight Resistance (SUN RES) nach UL Std. 1581 Sec. 1200
Notities
-
- alternative denomination: RE-Y(St)YRY
-
- available also acc. to PAS 5308
-
- suitable for direct burial
-
- the conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only
-
- we also offer cable glands: HELUTOP® HT-MS-EX-d / e4
Toepassing
-
- For the transmission of digital and analog signals in harsh environments like oil, gas and petrochemical industries. The cables are suitable for fixed installation in dry and damp locations, open spaces and in underground networks.